55
5) TROUBLE SHOOTING OF DRY SYSTEM
✦
HEATER DRY
Function : heating the air during dry
• FAILURE MODE : * "H7" - The air cannot be heated to 10°C during 2 min.
• CHECKING METHOD : * Check the resistance of heater coil and replace with new one.
✦
Thermistor
Function : sensing the air temperature.
• FAILURE MODE : * The air cannot be heated even though water is supplied.
* "H1" - shot or cut-off
* "H3" - air temp. is reached over 150°C
• CHECKING METHOD : * Check the resistance of thermistor, replace with new one.
✦
FUSE TEMPERATURE
function : protecting from the fire hazard or overheating, if the temp., rises over 128°C, power supply will be cut-off.
• Pictures
• FAILURE MODE : Dry is not performed.
• CHECKING METHOD : Check if fuse is short, and replace with new one.
FIXED BY
WASHER
+SCREW
Содержание DWD-T120R
Страница 15: ...13 3 CABINET F ASSY ...
Страница 17: ...15 4 CABINET ASSY ...
Страница 19: ...17 5 BASE U AS ...
Страница 21: ...19 6 TUB ASSY ...
Страница 23: ...21 7 DUCT B AS DUCT PIPE AS G01 G02 ...
Страница 68: ...64 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor ...
Страница 70: ...66 8 WIRINGDIAGRAM ...