58
• Situation : PCB shows "H7".
cause)
☛
Dry heater is cut-off.
☛
Fuse temp. is cut-off.
repaire method)
☛
replace the Dry heater.
☛
replace the Fuse temp.
checking point
part name
checking results
repaire method
HEATER
SENSOR TEMP.
FUSE TEMP.
dry Heater is short or cut-off.
Thermistor is short or cut-off.
FUSE TEMPERATURE is cut-off.
replace the
dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
THERMISTOR
HEATER DRY
FUSE
TEMPERATURE
Содержание DWD-T120R
Страница 15: ...13 3 CABINET F ASSY ...
Страница 17: ...15 4 CABINET ASSY ...
Страница 19: ...17 5 BASE U AS ...
Страница 21: ...19 6 TUB ASSY ...
Страница 23: ...21 7 DUCT B AS DUCT PIPE AS G01 G02 ...
Страница 68: ...64 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor ...
Страница 70: ...66 8 WIRINGDIAGRAM ...