8. FUNCTION OF THE CONVENIENT SERVICE
25
FUNCTION OF THE CONVENIENT SERVICE
■
The test mode of the load movement
You can check the PCB ASS'Y and the condition of each load movement simply.
• The method to test the load movement
1
Plug the power cord.
2
Turn the program selector to the program 1.
(The indicator light of the Start/Hold button is on but not twinkles. If the indicator is twinkles, press the
Start/Hold button and turn the program selector to the off.)
3
Press the Rinse+ button 3times while press the Intensive wash button.
4
Whenever the Rinse hold button is pressed, each load movement is occurred as follows;
Door lock close
→
Hot valve on
→
Cold valve on
→
Pre wash valve on
→
Bubble pump on
→
Drain pump on