background image

29

1. Testing Mode

PCB and other electronic parts will be tested without water supply whether they are normal or not. 

1) Process : press power button --> press "SPIN" button 3 times with pressing "WASH" button --> 'L d' will be shown on LED --

> Whenever pressing "TEMP" button 1 time, below process will be occurred.

L  C (Lock Closed) --> F ( Fan Motor) ---> H (Hot V/V) --> C (Cold V/V) -> 

P (prewashing V/V)  -> d ( dry V/V) -> bb (bubble) -> dr (drain motor) -> 

L  O(Lock S/W Open)

2) More details

1

When turn on 'LOCK' singal, all process is conducting normaly.

2

When working starts, the PCB displys all the sensor conditions.

3

In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.

2. Continous testing mode

1) Process : after pressing "WASH", "RINSE", "SPIN" button simultaniously, press "POWER" button. 

ALL LED On/Off 1 time --> L  C (Lock Closed) ---> R (Motor right) --> L (Motor Left) -->  F ( Fan Motor) ---> H

(Hot V/V)  --> C (Cold V/V)  --> b (pre-wash V/V) 

--> d ( dry V/V) --> bb (bubble) --> h1 (HEATER WASH)--> h2(HEATER DRY) --> dr (DRAIN MOTOR On) --

>L  O(Lock S/W Open)

2) More tails

1

LED test can be done with all LED On.

2

All sensor conditions will be shown on PCB during processing.

3. Convenience service functions(test mode)

Содержание DWD-E6213

Страница 1: ... S M No WDE1211001 Dec 2005 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center ...

Страница 2: ...FICATION OF DRUM WASHING MACHINE 6 3 VERIFICATION OF DRUM ASSY 7 4 PARTS LIST FOR EACH ASSY 8 5 SEQUENCE CHART OF PCB 23 6 TROUBLE SHOOTING 31 7 WIRING DIAGRAM 47 8 TROUBLESHOOTING REGARDING DRAIN 55 9 INSTALLATION GUIDE 56 10 ATTENTION POINT WITH SERVICE 58 ...

Страница 3: ...chnology Sterilizing up to 99 9 No damage and entanglement but excellent washability 4way savings noise vibration washing times energy Self cleaning course of Drum Good washing performance with heating system Condensing dry system with saving energy Sunshine dry effects with infrared x ray Big door glass with easy laundry take in out The higest spin speed 1200rpm 2 Salespointofourwasher ...

Страница 4: ...3 DD CONTROL DIRECT DRIVE SYSTEM BLDC MOTOR 3 THE DIRECT DRIVE SYSTEM OF DRUM WASHING MACHINE TUB DRUM LIFTER WASH BLDC DRAIN PUMP MOTOR ...

Страница 5: ... W ADDING CLOTHES LOCK HINGE DOOR AS GLASS GASKET 7 DRAIN PARTS DRAIN PUMP MOTOR VALVE HOUSING DRAIN HOSE I 6 DRY PARTS HEATER DRY OPTION BLOWER FAN FAN MOTOR BLDC THERMISTOR THERMOSTAT FUSE BI METAL CONDENSING SYSTEM DRY FAN DRIVE GENERATION OF HEATER S HEAT TEMP SENSOR 100 C OFF 90 C ON OPTION DRAIN PARTS ...

Страница 6: ...CB HARNESS NOISE FILTER POWER CORD 15A 2 DRIVE PARTS BLDC MOTOR DRUM BEARING SPIDER SHAFT TUB WEIGHT BALANCER 4 WASH HEATING WASH HEATER OPTION THERMISTOR 40 C FIXED TEMP CONTROL OPTION 60 C 90 C BOIL 8 SUPPORTER BASE DAMPERAS 3 70N ...

Страница 7: ...S 4 1 GLASS DOOR 4 2 HINGE DOOR 4 3 DOOR LOCK S W 6 WASH HEATING WASH HEATER THERMISTOR 5 DRY DUCT B AS 2 PARTS for DRIVING 2 1 LIFTER AS 2 2 GASKET 2 3 WEIGHT BALANCER 2 4 ROTOR 2 5 STATOR 2 6 SHAFT 2 7 BEARING 2 8 SPIDER 2 9 DRUM 2 10 TUB 2 11 BASE BLDC MOTOR PARTS for TRANMITTING FAN MOTOR 2 9 2 6 2 7 2 4 2 5 2 11 2 10 TEMP FUSE BI METAL S W HEATER DRY TEMP SENSOR 2 7 2 8 FAN ...

Страница 8: ... AS 7 2 HOSE DRAIN I 7 3 HOSE DRAIN 8 SUPPORTER 8 1 BASE U 8 2 DAMPER AS 3 70N 8 3 SPRING FRONT 2 BLACK REAR 2 YELLOW 5 3 3 3 2 1 2 2 2 4 3 4 1 4 2 2 3 7 2 7 1 8 1 7 3 8 2 1 1 1 3 2 1 6 8 3 EMP FUSE 3 1 ATER DRY TEMP SENSOR ...

Страница 9: ...YPE DRUMTYPE DRYTYPE Digitalcondensingdrysystem OPERATIONWATERPRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 NO PARTS NAME 1 FRME DOOR O 2 DOOR WINDOW 3 DCD STICKER 4 PANEL LOWER 5 CABINET FRONT 6 PANEL LOWER 7 FRAME TOP F 8 FRAME TOP R 9 CABINET 10 PLATE TOP 11 CASE HANDLE 12 HANDLE CAP 13 BADGE 14 WINDOW DISPLAY 15 DECO WINDOW 16 BUTTONDOORUNLOCK 17 BUTTON FUNCTION 18 DECO FUNCTION 19 PLATE DISPENSER...

Страница 10: ...7 3 VERIFICATIONOFDRUM ASSY ...

Страница 11: ...7 ...

Страница 12: ...01 FRAME PLATE F 3612204400 HIPS 1 A02 FRAME PLATE REAR 3612204500 HIPS 1 A03 PLATE TOP 3614531600 WOOD 1 A04 PAD CUSHION 3614110500 SPONGE 1 A05 FIXTURE PLATE T 3612007100 STAPLE 8x10 1 SCREW TAPPING 7122401411 T2S TRS 4x14 MFZN 2 A06 PANEL LOWER 3614284200 HIPS 1 A07 COVER PRMP 3611426400 HIPS 1 ...

Страница 13: ...09 BUTTON FUNCTION 3616602700 ABS UV_BASE 1 SCREW TAPPING 7121301508 T2S PAN 3x15 MFNI 3 B10 WINDOW DISPLAY 3615502700 ABS TR558 1 B11 DECORATOR WINDOW 3611630800 ABS GILDING_BASE 1 B12 HOLDER POWER 3613048800 ABS TR558 1 B13 HOLDER COURSE MAIN 3613049100 ABS 1 B14 BUTTON DIAL MIDDLE 3616602400 ABS GILDING_BASE 1 B15 BUTTON DIAL OUT 3616602500 ABS TR558 1 B16 BUTTON DIAL IN 3616602300 ABS GILDING_...

Страница 14: ...N DOOR OPEN 3616603200 ABS 1 B07 BUTTON FUNCTION 3616603000 ABS 1 SCREW TAPPING 7121301208 T2S PAN 3x12 SUS 3 B08 HOLDER LED COURSE 3613049300 ABS 1 B09 HOLDER LED CUSTOM 3613049200 ABS 1 B10 CASE PCB F 3611139600 HIPS 1 SCREW TAPPING 7122401411 T2S TRS 4x14 MFZN 7 B11 PCB PRPSSW2D10 1 B12 SUTTON DIAL OUT 3616603400 ABS 1 B13 BUTTON DIAL IN 3616603300 ABS 1 B14 WINDOW DISPLAY 3615502800 ABS BK 841...

Страница 15: ...0 ABS 1 B02 HOLDER LED COURSE 3613049500 ABS 1 B03 HOLDER LED CUSTOM 3613049200 ABS 1 B04 CASE PCB F 3611139900 HIPS 1 B05 PCB PRPSSW4D10 1 SCREW TAPPING 7122401411 T2S TRS 4x14 MFZN 3 B06 DECORATOR FILM 3611632600 PC FILM 1 B07 CASE HANDLE 3611139800 ABS 1 INLETBOX AS Cheap ...

Страница 16: ...12 3 CABINETFAS ...

Страница 17: ...00 PP 1 C09 STOPPER DOOR 3615202300 PP 3 C10 SCREW TAPPING 7122401608 T2S TRS 4x16 SUS 2 C11 SCREW TAPPING 7115402008 T1S FLT 4x20 SUS430 NATURAL 15 C12 DOOR GLASS 361A110600 GLASS DWD 100DR 1 C13 PROTECTOR GLASS 3618304201 ABS TRANSPATENT 1 C14 FRAME DOOR O 3612204600 ABS 1 CR C15 COVER HANDLE 3611425620 ABS 1 CR C16 SPRING HOOK 3615113700 SUS ID 3 NI 7 D ø0 9 2 C17 PIN HANDLE 3618200100 SUS D 3 ...

Страница 18: ...16 L 165mm 2 PRE WASH D11 HOSE A 3613266600 EPDM ID 10 OD 16 L 335mm 1 MAIN WASH D12 HOSE B 3613266700 EPDM ID 10 OD 16 L 420mm 1 HOT D13 CLAMP SPRING 3611203800 ID 15 5 T 0 6 B 10 8 D14 VALVE INLET 3615415900 100 130V 3WAY PP BRACKET 1 COLD 3615415000 220 240V 50 60Hz 3WAY 1 COLD 3615415010 220 240V 3WAY NYLON BRACKET 1 COLD VDE 3615415800 100 130V 2WAY PP BRACKET 1 COLD 3615414900 220 240V 50 60...

Страница 19: ...15 5 DUCT DUCTPIPEAS ...

Страница 20: ...G THERMOSTAT 3614009900 SILICON 1 E12 SWITCH THERMOSTAT 3619046500 ON 120 C OFF 150 C 230V 1 E13 HEATER DRY 3612800900 220V 210W 23 050HM 6 1W SQ 1 3612801400 230V 2 1KW 25 190HM 6 1W SQ 1 3612801600 240V 2 1KW 27 430HM 6 1W SQ 1 3612801300 110V 1 2KW 10 080HM 3 5W SQ 1 3612801800 120V 1 2KW 120MH 3 5W SQ 1 E14 THERMISTOR DRY 361AAAAC00 R40 26 065k R90 4 4278k 1 E15 PACKING RUBBER 3614009800 SILIC...

Страница 21: ...17 6 CABINETAS ...

Страница 22: ... 3512204200 SBHG 1 2T DWD 100DR 1 F11 HOSE DRAIN I 3613269500 ST EL 840M 1 F12 CUFF DRAIN HOSE 3616802600 PP PUMP 1 F13 HOSE SIPHON 3613269600 EPDM 1 F14 CLAMP HOSE 3611204700 D 27 1 F15 CORD POWER AS 3611339910 H05VV F 1 5SQx3C 250V16A 1 EU 2PIN 3611339930 H05VV F 1 5SQ 250V16A FERRITE 1 EU 2PIN 3611339510 250V15A IEC53 1 5SQx3C 1 CP 2PIN 3611339310 H05VV F 1 5SQx3C 250V16A CP 2PIN 3611339810 VCT...

Страница 23: ...19 7 BASEUAS ...

Страница 24: ...91910 PP DWD 100DR 1 G04 UNIT FILTER EMI K19 3611908000 220V FUSE250V 471 474 10MH 1 3611908010 100V FUSE125V 471 474 10MH 1 G05 SUPPORTER LEG 3615303600 PO 3 0T 4 G06 FIXTURE LEG 3612006400 ABS DWD 100DR 4 G07 FOOT 3612100600 BUTYL DWD 100DR 4 SPECIAL BOLT 3616029000 10x1 25 51mm 4 G08 HARNESS AS 3612795510 E1211W DOUBLE VALVE 1 BUBBLE 3612795515 E1211W DOUBLE VALVE 1 N BUBBLE 3612795550 E1211W S...

Страница 25: ...21 8 TUBAS ...

Страница 26: ... PP PUMP 1 H16 HOSE DRAIN 3613269000 EPDM PUMP 1 H17 AIR TRAP AS 3610AAR101 110RP HOSE TRAP 1 H18 SPRING SUSPENSION R 3615113600 BLACK 2 H19 GASKET TUBE 3612321100 EPDM FORM 1 H20 WATER SEAL 361A600100 NBR 1 H21 BEARING INNER 3616303100 6206Z FAG 1 H22 BEARING HOUSING 3616303000 ALDC 1 H23 BEARING OUTER 3616303200 6205Z FAG 1 H24 HOSE AIR 3613266300 EPDM 1 H25 UNIT BUBBLE PUMP 36189L4110 220 240V ...

Страница 27: ...ain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 1 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 1min 7min Main Spin 5min 3min Crease care 60sec END 10sec Remain Time Display 1 27 1 32 1 27 1 55 2 22 2 32 1 37 1 52 NOTE Pre Wash W a s h i n g R ...

Страница 28: ... 1min Balancing Spin 1min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 1min 7min Mid Spin 5min 3min Crease care 60sec Dry 15min 10min Cooling 5min END 10sec Crease care 30min Crease care 60sec END 10sec Remain Time Display 46 46 1 07 1 10 1 48 NOTE W a s h i n g R i n s e S p i n D R Y End Wool Delicate Blanket Rapid Drum cleaning Memory 1 In Rapid and Drum cleaning progr...

Страница 29: ...ng the same 45 rpm with left and right direction alternatively 2 Attaching stop Attaching the laundry to drum inside with constant speed 3 Unbalance checking point First step check the U B at 95 rpm 160 rpm Second step check the U B at 95 rpm 350 rpm Third step at 300 rpm if the unbalance data is over the criterion This process will be repeated 4 Drain step Drain at water around 160 rpm 5 After dr...

Страница 30: ...msec pulse until unlock 3 After door locking all parts can work normally 4 After pressing power button if the temperature of wash thermistor is over 50 C or the water level is over the safety level the door will be locked 6 The door will be unlocked immediately after all processes are finished 7 The door can be opened during processing if there is no problem to unlock ...

Страница 31: ...Display LOCK off Dooropen drain fanmotoron coldwatersupply waterlevelis lessthansafetylevel NO NO YES YES Temperatureis lessthan50 C 2 DOOROPENSYSTEM 1Ifaddthelaundryduringwashing pressthedoorunlockbutton 2Dooropensequenceatabnormalcondition ...

Страница 32: ...k mode press TEMP and DRY simultaneously 2 5 The sequence of drain 1 If the checking time to reset point is below 1 min the remaining drain time is 30 sec 2 If the checking time to reset point is over 1 min the remaining drain time is 2 min 3 If the checking time to reset point is over 10 min OE singal will be appeared on PCB 4 If the temperature is over 50 C the water will be supplied to high wat...

Страница 33: ...urnon LOCK singal allprocessisconductingnormaly 2Whenworkingstarts thePCBdisplysallthesensorconditions 3Inthiscase BLDCMotorisnottested Inordertotestit selectspinorrinse 2 Continoustestingmode 1 Process afterpressing WASH RINSE SPIN buttonsimultaniously press POWER button ALLLEDOn Off1time L C LockClosed R Motorright L MotorLeft F FanMotor H HotV V C ColdV V b pre washV V d dryV V bb bubble h1 HEA...

Страница 34: ... VOLTAGE 2 spiningwithjammingclothesbetweengasket rearrangethelaundry ERROR 3 PCBbroken ChangethePCB 1 hugenoise re installation E6 EMG ERROR 2 spiningwithjammingclothesbetweengasket rearrangethelaundry 3 motorbroken ChangetheMotor 4 PCBbroken ChangethePCB E7 DirectionError 1 moveoppositedirection 2 motorHallICbroken checktheconnectorandchange E8 motordisorder 1 connectorproblem ThecontactoftheCon...

Страница 35: ...y assembled Openthewatertap Cleanthefilter ChangetheInlet Valve Thecontactofthe Connector ChangetheInlet Valve ChangetheSensor Pressure Changethebad parts ChangetheInlet Valve ChangetheInlet Valve IE IE IE IE IE IE IE E2 E2 checkthewatertapopened checktheresistance4320 5280Ω checkthefilter checktheconnector checktheresistance4320 5280Ω checktheconnector checkthepressureswitch checkthehosetornortwi...

Страница 36: ...checkthehosecondition checktheconnectorcondition frequencyCheck refertobelow connectorbroken Checkingmethodofcoilregistance harness connector E2 overflowerror Waterlevelishigherthanoverflowlevelbecauseofcontinuouswatersupply E9 Pressureswitchtrouble thefrequencyislessthan15kHzormorethan30kHzintheprocessing Checking method of the Frequency 1 Power ON 2 First press the DRY button 3 times with pressi...

Страница 37: ... CloseDoorsecurely ReplaceDOORAS ReplaceDOORS W AssembleConnector InsertReceptacleno 2 orno 3 ReplaceDOORS W Afterdrainingwater openthedoor LE LE LE LE LE LE LE checkthejoiningstatusof connectorbyeye Ticksoundhappen checkthejoiningstatusof connectorbyeye Refertobelowchecking method Refertobelowchecking method Checkwhetherthewater levelisoversafetylevel WhenDoorislocked unlocked thisSolenoidWorking...

Страница 38: ...34 2 CheckingmethodofDOORLOCKSWITCH 3 CheckingmethodofDOORLOCKSWITCH 2345 Nono 1 BetweenNo 3 No 4 if156 234Ω itisnormal BetweenViloetandBluewire If156 234Ω itisnormal PIN array ...

Страница 39: ... the resistancebetweentwoendsis23 3 25 7Ω Checkwhetherdisconnectedornot SeeFig A Measuretheresistanceoftwoendsofthesensor if 11 981KΩatR25 itismormal Measuretheresistanceoftwoendsofthesensor if 11 981KΩatR25 itismormal Checkwhetherdisconnectedornot SeeFig B Checkwhetherdisconnectedornot ifnormal the resistancebetweentwoendsis22 3 24 7Ω Shippedout Checkwhetherdisconnectedornot SeeFig B ExcessiveNoi...

Страница 40: ...torDryOPEN SHORT 2 H2 ThermisterWashOPEN SHORT 3 H3 DryOverheating SensingTemp isover125 4 H4 WashOverheating SensingTemp isover95 5 H5 Wash Overheating InWool Lingeriecoursessensingtemp isover45 6 H6 Abnormal condition of Heater Wash whenthetemp increaseat10minutesafterheateroperationisunder10 7 H7 Abnormal condition of Heater Dry when the temp increase at 10 minutes afterheateroperationisunder10...

Страница 41: ...DrivingmechanismofBLDCMOTOR BLDCMOTOR MagneticdensityflowofBLDCMotor SequencediagramofBLDCMOTOR 5 MOTOR Rotor Insulator Core Insulator electromagnet generatinghighpowerbyrotator apermanentmagnet andstator multiplecoils ...

Страница 42: ...RY SYSTEM F H I A B C D E G J DIVISION PARTSNAME A DUCTCOVER B FANMOTOR C HEATERDRY D DUCTBUNDER E VALVEINLET DRY F THERMOSTAT Bie METAL G THERMISTOR H DUCTBUPPER I FANAS J FUSETEMPERATURE 6 DRY SYSTEM OPTION ...

Страница 43: ...T andcondensedinDUCTcontactingWATERSUPPLY condensedwater isextractedthroughDRAINHOUSING Dryfunctionisperformedbycontinuousrepetitionofevaporatingandcondensingcirculationasabove DRY DUCT T Thermistor CONTROL HEATER S TEMPERATURE HEATER FANMOTOR CONDENSING DUCT DRUM DRAIN HOUSING 온도 건조진행구간 예열 구간 DRUM 내부온도 시간 T WATER SUPPLY INSIDE TEMPERATURE OF DRUM TIME DRYING PROCESS ZONE TEMP PREHEATING ZONE ...

Страница 44: ...s87 COn 95 COff dryingtimeis166min STRONG Heatercontroltemperatureis87 COn 95 COff dryingtimeis216min SELECTINGTIME Heatercontroltemperatureis87 COn 95 COff customercanselectthedrytingtimeas 1Hr 2Hr 3Hr Inordertocheckthedryingtemperatureduringprocessgoingon pressthe DRY button thedisplayshowsasbelow 남은시간 분 UPPER LED TemperatureforDRY Thecurrenttemperatureis98 LOWERLED TemperatureforWASH REMAINTIME...

Страница 45: ...ingtheairtemperature FAILUREMODE Theaircannotbeheatedeventhoughwaterissupplied H1 shotorcut off H3 airtemp isreachedover150 C CHECKINGMETHOD Checktheresistanceofthermistor replacewithnewone FUSETEMPERATURE function protectingfromthefinehazardoroverheating ifthetemp risesover128 C powersupplywillbecut off Pictures FAILUREMODE Dryisnotperformed CHECKINGMETHOD Checkiffuseisshort andreplacewithnewone ...

Страница 46: ...50 C andreoperatingheater byconnectingheaterpowersupplyifthetemperaturefallsunder120 C OPERATINGTEMPERATURE PICTURE UNITFANMOTOR function circulatingtheinsideairduringdryprocess SPEC PICTURE FAILUREMODE E3shown FANMOTORcannotwork CHECKINGMETHOD ChecktheFANMOTORisshort andreplacewithnewone OPEN TEMPERATURE OFF 150 5 CLOSETEMPERATURE ON 120 5 ITEMS SPEC RATING VOLTAGE 24V RPM MOTOR 3700 10 DUCT FAN ...

Страница 47: ... redrayfromceramicparticlecoatingonDUCT BUPPER principle DUCT B UPPER FAR INFRAREDCOATING DUCT B UPPER heatedair emitfar infrared f a r i n f r a coatingarea steilization The far infrared ray is emitted from the ceramic coating comes into drum by radiation and reflection and penetrates deeply into laundry with the effective moisture removal and sterilization pass tubinside ...

Страница 48: ...asdonebeforethedryhadstarted Situation PCBshows H1 or H3 cause Thermistorisbroken Thermistorisshortorcut off countermeasures replacetheThermistor part name checking point checking results jurge repair method BELLOWS DUCT VALVE INLET Condensing HOSE clogging bellowsduct nowatersupply frominletvalve heaterwas overheated owingtopoorair circulation VALVEINLET connectorslipped out VALVEINLET broken ill...

Страница 49: ...ryheater replacetheFusetemp checking point part name checking results repaire method HEATER SENSORTEMP FUSETEMP dryHeaterisshortorcut off Thermistorisshortorcut off FUSETEMPERATUREiscut off replacethe dryHeater replacethe Thermistor replacethe FUSE TEMPERATURE HEATER THERMISTOR FUSE TEMPERATURE ...

Страница 50: ...ilure replace fanmotor 1DisassembletheDUCTASfromDUCTBAS SCREW4EA 2DisassembleFANASfromDUCTCOVERASbyusing L wrench 3DisassembleFANMOTOR SCREW3EA DUCT COVER AS 2 5mm L wrench parts Control time MOTOR 10 sec On 10sec Off DRAIN MOTOR Continous working FANMOTOR Continousworking DRY HEATER 87 C On 95 C Off INLET VALVE 5sec On 20sec Off Remarks controltimesofeachpartsduringdryprocess ...

Страница 51: ...47 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE 7 Wiring Diagram ...

Страница 52: ...48 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE ...

Страница 53: ...49 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE ...

Страница 54: ...50 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE ...

Страница 55: ...51 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE ...

Страница 56: ...52 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE ...

Страница 57: ...53 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE ...

Страница 58: ...54 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE ...

Страница 59: ...ingdrainduring10min ThewaterlevelcannotreachtoRESETPOINTduring10minofdrain Checking Methods Check the hose drain O condition twisted or frozen Check the hose drain O condition blocked DRAIN MOTOR is broken Replacing methods replace HOSE DRAIN O clean the inside of Filter replace DRAIN MOTOR ...

Страница 60: ... AS by turning CCW direction Please keep FIXTURE UP DOWN AS for later use When fixing FIXTURE UP DOWN AS turn it CW direction PARTS NAME FIXTUREUP DOWNAS UNIT SERVICE WRENCH LEG ADJUST AS REMARKS SPECIAL SCREW UP L 109mm SPECIAL SCREW DOWN L 145mm 1Usethisparttoremove FIXTUREUP DOWN 2Adjustlegwiththispart FIGURES SPECIAL SCREW UP FIXTURE UP FIXTURE DOWN FOOT FIXTURE LEG CAP HOLDER SPECIAL SCREW DO...

Страница 61: ...singLEGADJUSTAS Adjusting Method Remarks If turned CW the LEG ADJUST AS moves the washer upward If turned CCW the LEG ADJUST AS moves the washer downward 5Afteradjustinglevel fixSPECIALBOLT Adjusting Method Remarks Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration ...

Страница 62: ...lingconditionbetween fixtureheateristight littlegaponleft right Atfasteningthenutforfixingtheheaterwash keeptheprotrusionlength ofboltto10 12mm ifunder10mm watercanleak andifover12mm fixtureheatercan deform 7 Replacing ThermistorWash UnfastentheNutforfixingheater replacethethermistor and ThermistorWash fastenthenutforfixingheater 8 Assembling HingeDoor AtfasteningscrewforfixingDoorAS becarefulsoth...

Страница 63: ...2005 09 DRUM WASHING MACHINE 본사 서울마포구아현동686 소비자상담실 대표 360 8282 http www dwe daewoo co kr ...

Отзывы: