32
2) PRESSURE SWITCH
TROUBLE
SITUATION
CAUSE
CHECK POINT
SOLUTION
PCB
ERROR MODE
continuously
water supply
"E9"
ERROR
inlet valve is normal,
but continuous water
supply
water level frequence
below 15kHz or over
30kHz
bellows problem
hose problem
clogged hose
connector slipped out
pressure switch broken
connector short
change the
pressure switch
change the hose
change the hose
remove the alien
reconnecting
change the
pressure switch
"E2"
"E2"
"E2"
"E2"
"E9"
"E9"
"E9"
frequency Check : refer to below
frequency Check : refer to below
check the fine hole
check the hose condition
check the connector condition
frequency Check : refer to below
connector broken
Checking method of coil registance, harness, connector.
* E2 : overflow error ;Water level is higher than overflow level because of continuous water supply.
E9 : Pressure switch trouble, the frequency is less than 15kHz or more than 30kHz in the processing.
■
Checking method of the Frequency
1
Power ON
2
First, press the “DRY” button 3 times with pressing
the “WASH” button. The frequency of Air status will
be appeared.
ex) 623
➝
26.23kHz.
3
Press “TEMP” button
1 time: water supply
2 times: stop the water supply
3 times: start the drain
4 times: stop the drain
5 times: return to Air status mode
GROUND(GRAY)
OUTPUT
SIGNAL(WHITE)
INPUT SIGNAL
(PINK)
"12P" WHITE CONNECTOR
Содержание DWD-E6213
Страница 10: ...7 3 VERIFICATIONOFDRUM ASSY ...
Страница 11: ...7 ...
Страница 16: ...12 3 CABINETFAS ...
Страница 19: ...15 5 DUCT DUCTPIPEAS ...
Страница 21: ...17 6 CABINETAS ...
Страница 23: ...19 7 BASEUAS ...
Страница 25: ...21 8 TUBAS ...
Страница 51: ...47 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE 7 Wiring Diagram ...
Страница 52: ...48 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE ...
Страница 53: ...49 DWD E1211R DOUBLE VALVE BUBBLE DWD E1211R DOUBLE VALVE N BUBBLE ...
Страница 54: ...50 DWD E1221R DOUBLE VALVE BUBBLE DWD E1221R DOUBLE VALVE N BUBBLE ...
Страница 55: ...51 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE ...
Страница 56: ...52 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE ...
Страница 57: ...53 DWD E1211W DOUBLE VALVE BUBBLE DWD E1211W DOUBLE VALVE N BUBBLE ...
Страница 58: ...54 DWD E1221W DOUBLE VALVE BUBBLE DWD E1221W DOUBLE VALVE N BUBBLE ...
Страница 63: ...2005 09 DRUM WASHING MACHINE 본사 서울마포구아현동686 소비자상담실 대표 360 8282 http www dwe daewoo co kr ...