![Daewoo DWC-ED1213 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/daewoo/dwc-ed1213/dwc-ed1213_service-manual_3309099049.webp)
45
• Situation : PCB shows "H7".
cause)
Dry heater is cut-off.
Fuse temp. is cut-off.
repaire method)
replace the Dry heater.
replace the Fuse temp.
checking point
part name
checking results
repaire method
HEATER
SENSOR TEMP.
FUSE TEMP.
dry Heater is short or cut-off.
Thermistor is short or cut-off.
FUSE TEMPERATURE is cut-off.
replace the
dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
HEATER
THERMISTOR
FUSE TEMPERATURE
Содержание DWC-ED1213
Страница 10: ...7 3 VERIFICATIONOFDRUM ASSY...
Страница 11: ...7...
Страница 16: ...12 3 CABINETFAS...
Страница 19: ...15 5 DUCT DUCTPIPEAS...
Страница 21: ...17 6 CABINETAS...
Страница 23: ...19 7 BASEUAS...
Страница 25: ...21 8 TUBAS...
Страница 51: ...47 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE 7 Wiring Diagram...
Страница 52: ...48 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 53: ...49 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 54: ...50 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 55: ...51 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 56: ...52 DWC E1213 DOUBLE VALVE BUBBLE DWC E1213 DOUBLE VALVE N BUBBLE...
Страница 57: ...53 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 58: ...54 DWC ED1213 DOUBLE VALVE BUBBLE DWC ED1213 DOUBLE VALVE N BUBBLE...
Страница 63: ...2005 09 DRUM WASHING MACHINE 686 360 8282 http www dwe daewoo co kr...
Страница 64: ...SVCMANUAL DWD E1200R S DWD E1200W S 2005 09 DRUM WASHING MACHINE DRUMWASHINGMACHINE...