background image

7

6. CARE AND MAINTENANCE

1. AIR FILTER

Clean the air filter, which removes dust inside the room.
It should be washed at least once every week during operation.
1. Remove the Air Filter from the front grill by pulling up.
2. Clean Air Filter with a vacuum cleaner or lukewarm, soapy water.
3. Shake it when clean to remove moisture completely. Replace it.

2. CLEANING THE AIR CONDITIONER

1. At least once a year, remove cabinet and thoroughly clean air conditioner. Have the unit inspected by an authorized

servicer to ensure unit is functioning properly.

2. Wash air conditioner with lukewarm, soapy water as needed. Rinse and dry thoroughly.
3. If using concentrated liquid detergent, dilute in warm water first.
4. Front grill may be wiped off with a cloth dampened in a mild detergent solution.
5. Cabinet may be washed with mild soap or detergent and lukewarm water, then polished with liquid wax for 

appliances.

6. Condenser and Evaporator coils should be cleaned at the beginning of each cooling season. Use a soft brush or 

vacuum cleaner to clean them, making sure that the Condenser and Evaporator coils are not damaged.

7. Do not use abrasive cleaners. These items scratch, crack and discolor surfaces. 

Содержание DWC-056C

Страница 1: ...FEB 2005 Model DWC 056CL DWC 056C DWB056C001 Window Type Room Air Conditioner ...

Страница 2: ...CATIONS 3 3 NAMES OF MAJOR COMPONENTS 4 4 FUNCTION OF MAIN COMPONENTS 5 5 GENERAL INFORMATIONS 6 6 CARE AND MAINTENANCE 7 7 TROUBLE SHOOTING GUIDE 8 8 HOW TO DISASSEMBLE 10 9 WIRING DIAGRAM 11 10 REFRIGERANT CYCLE 12 11 EXPLODED DIAGRAM AND PARTS LIST 13 ...

Страница 3: ...pair the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage power cord 6 Never use connecting the middle of wire after cutting the middle of wire It may cause a fire and trouble 7 Checking the insulation resistance After you complete the assembly of unit surely...

Страница 4: ...ning Current A 5 0 2 5 Compressor Type ROTARY Model 39R131ER 54P 39A052JSAJA Capacitor 35µF 250VAC 20µF 400VAC Model YSLA 28 6 0004 YSLA 35 4 0006 Fan Motor Capacitor 4µF 250VAC 2µF 400VAC Indoor Fan Blower Fan Outdoor Fan Propeller Fan Refrigerant R 22 Control Capillary Charge Amount g 11 3oz 320g 12 3oz 350g Dimensions Unit W x H x D 16 9 W x11 4 H x12 8 D inch 430 W x289 H x325 D mm PACKING W x...

Страница 5: ...RTICAL 3 COOL AIR DISCHARGE 4 GRILLE FRONT 5 KNOB THERMOSTAT 6 SWITCH POWER 7 SWITCH FAN NO PART NAME 8 AIR INTAKE 9 AIR FILTER 10 CONTROL PANEL 11 PLATE WINDOW TOP 12 FRAME WINDOW KIT 13 SHUTTER WINDOW DWC 056CL DWB 056C 1 6 5 0 2 3 9 8 7 q w 4 e 1 2 3 8 6 5 0 7 4 ...

Страница 6: ...ut 5 CAPACITOR The Capacitor enlarges the difference of phase between main coil and sub coil so that the Compressor and Fan Motor starts well 6 ACCUMULATOR The Accumulator blocks the unflow of liquid refrigerant and impurities into the Compressor ON Select this setting to turn on the unit OFF Select this setting to turn off the unit HIGH Select this setting for maximum air circulation LOW Select t...

Страница 7: ...eptacle replaced with a properly grounded three prong wall receptacle in accordance with the National Electrical Code 4 USE OF EXTENSION CORDS ONLY DWB 056C Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if you still elect to use an extension cord it is absolutely necessary that it is earthed and the marked rating of ...

Страница 8: ...zed servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Front grill may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliance...

Страница 9: ...nection 2 Malfunction of contact Disconnection or burned out 1 Failure 2 Malfunction 3 Knob is not set to the proper setting Failure of malfunction of proper setting 1 Disconnection 2 Malfunction of contact Lack of capacity Disconnection 1 The voltage exceeded allowed range 2 Capacity of wire is not sufficient Extremely high Burned out Malfunction Lack of capacity Malfunction Lack of capacity Malf...

Страница 10: ...of refrigerant gas 4 Refrigerant charge is too high Clogged up with dust 1 Fin is cogged up with dust 2 The ventilation is not good 3 The unit is exposed to the sunlight 4 Other heat source is added in the room Installation of the unit is imperfectly done 1 Fan is contacted with obstacles 2 Fixing bolt Have a screw loose Electrical noise The front is lower than rear side 1 Insulation defect of wir...

Страница 11: ... 1 Remove Front Grill Remove Filter Pre Remove screws 2 points in Front Grill 2 Remove Cabinet from the unit Remove screws 7 point from the unit s sides 3 Remove screw 1 point from Earth Wire and EVA end plate 4 Remove clamp cord Remove screw 1 point from the Pan Base 5 Remove Ass y Control Box Remove wires in the each components 6 Remove Plate Scroll and Scroll Upper Remove Sealing Scroll from tw...

Страница 12: ...11 9 WIRING DIAGRAM ...

Страница 13: ...12 Condenser Propeller fan Capillary tube Compressor Accumulator Blower fan Evaporator M MOTOR 10 REFRIGERANT CYCLE ...

Страница 14: ......

Страница 15: ...14 DWC 056CL DWB 056C EXPLODED DIAGRAM ...

Страница 16: ...4 ...