- 3 -
Service manual SP-110
Ac Line Voltage
Region
Load Z
Leakage Current(
i
) Clearance Distance(d),(d’)
1-4. Leakage current test
Confirm specified or lower leakage current between
B(earth ground, power cord plug prongs) and externally
exposed accessible parts (video and audio input termin-
als, speaker out, etc.)
Measuring method:(Power ON) lnsert load Z between
B(earth ground, power cord plug prongs) and exposed
accessible parts. Use AC voltmeter to measure AC voltage across both terminals of load Z. See Fig.2 and
following table.
Leakage current ratings for selected are as
NOTE
This table is unofficial and for reference only. Be sure to confirm the precise values
for your particular country and locality.
100V
Japan
1
i
1mArms.
Exposed accessible parts
110 to 130V
USA & Can-
ada
1
15 F
i
0.5mArms.
Exposed accessible parts
2
i
0.7mA peak
i
2mAdc
Antenna earth terminals
110 to 130V
200 to 240V
Europe
Australia
50
Other terminals
i
0.7mA peak
i
1mAdc