32
INSTALLATION MANUAL---Information for the installer
FIXED-SPEED TYPE
MODEL capacity (Btu/h)
5k
7k
9k
12k
15/18k
22/24k
28/30k
Liquid pipe diameter
1/4
(
6)
1/4
( 6)
1/4
( 6)
1/4
( 6)
1/4
( 6)
3/8
(
9.52)
3/8
(
9.52)
Gas pipe diameter
3/8
(
9.52)
3/8
(
9.52)
3/8
(
9.52)
1/2
(
12)
1/2
(
12)
5/8
(
15.88)
5/8
(
15.88)
Lenght of pipe with standard charge
3m
3m
3m
3m
4m
4m
4m
Maximum distance between indoor and outdoor unit
15m
15m
15m
15m
15m
15m
15m
Additional refrigerant charge
20g/m
20g/m
20g/m
20g/m
30g/m
30g/m
30g/m
Max. diff. in level between indoor and outdoor unit
5m
5m
5m
5m
5m
5m
5m
Type of refrigerant(1)
R22
R22
R22
R22
R22
R22
R22
FIXED-SPEED TYPE
MODEL capacity (Btu/h)
7k
9k
12k
15/18k
22/24k
28/30k
Liquid pipe diameter
1/4
( 6)
1/4
( 6)
1/4
( 6)
1/4
( 6)
3/8
(
9.52)
3/8
(
9.52)
Gas pipe diameter
3/8
(
9.52)
3/8
(
9.52)
3/8
(
9.52)
1/2
(
12)
5/8
(
15.88)
5/8
(
15.88)
Lenght of pipe with standard charge
3m
3m
3m
4m
4m
4m
Maximum distance between indoor and outdoor unit
15m
15m
15m
15m
15m
15m
Additional refrigerant charge
20g/m
20g/m
20g/m
30g/m
30g/m
30g/m
Max. diff. in level between indoor and outdoor unit
5m
5m
5m
5m
5m
5m
Type of refrigerant(1)
R410A
R410A
R410A
R410A
R410A
R410A
INVERTER TYPE
MODEL capacity (Btu/h)
9k
12k
15/18k
22/24k
Liquid pipe diameter
1/4
( 6)
1/4
( 6)
1/4
( 6)
3/8
(
9.52)
Gas pipe diameter
3/8
(
9.52)
3/8
(
9.52)
1/2
(
12)
1/2
(
12)
5/8
(
15.88)
Lenght of pipe with standard charge
3m
3m
3m
4m
4m
Maximum distance between indoor and outdoor unit
15m
15m
15m
15m
15m
Additional refrigerant charge
20g/m
20g/m
20g/m
30g/m
30g/m
Max. diff. in level between indoor and outdoor unit
5m
5m
5m
5m
5m
Type of refrigerant(1)
R410A
R410A
R410A
R410A
R410A
(1) Refer to the data rating label sticked on the outdoor unit.
TIGHTENING TORQUE FOR PROTECTION CAPS AND FLANGE CONNECTION
PIPE
TIGHTENING TORQUE
[N x m]
CORRESPONDING STRESS
(using a 20 cm wrench)
TIGHTENING TORQUE
[N x m]
1/4
(
6)
15 - 20
wrist strength
Service port nut
7 - 9
Содержание DSB-F0969GLH-V
Страница 1: ......
Страница 3: ...1 PROTECTION 17 INSTALLATION MANUAL 18 MAINTENANCE 27 TROUBLESHOOTING 28 ...
Страница 8: ...6 NAMES OF THE PARTS ...
Страница 9: ...7 The conditioner is made up of two or more units ...
Страница 13: ...11 REMOTE CONTROL ...
Страница 15: ...13 REMOTE CONTROL ...
Страница 20: ...18 MODES OF OPERATION ...
Страница 21: ...19 ...
Страница 24: ...22 ...
Страница 25: ...23 ...
Страница 35: ...33 3 8 9 52 31 35 arm strength Protection caps 25 30 1 2 12 35 45 arm strength 5 8 15 88 75 80 arm strength ...