-34-
Trouble shooting
A) PDP Module Shut Down
Check Start
Disconnect AC power
Disconnect AC power
Disconnect AC power
Disconnect P1, P2 in Ysus B/D
and P10 in Zsus B/D
Turn on the set after
connection AC power
Is ’SHUT DOWN’ occurred?
Replace Ysus & Zsus B/D
N
Y
Is ’SHUT DOWN’ occurred?
N
Y
Connect P1 in Ysus B/D
Turn on the set after
connecting AC power
Replace CTRL B/D
Disconnect P814
& Connect P812
Done
Done
Disconnect AC power
Replace XL & XR B/D
Done