62
DES CR IP TIO N
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten
fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.
But in Secondary Wave Custom Code is Reversed Face.
LEADER CODE
CUSTOM
CODE
DATA
CODE
CHECK
SUM
TAILER
9ms
4.5ms
16bit
16bit
24bit
8bit
Fig 5-1
Fig 5-2
BIT STRUCTURE
Rem ote Controller(5 )
0.56ms
0.56ms
1.69ms
1.12ms
2.25ms
bit 0
bit 1
Selecting M ode(6 )
(SELECT S/W INPUT, OUTPUT)
MICOM
14
R5
1K
10K
R4
5V
CC7
103
P2
MODE
SELECT
PUSH S/W
DES CR IP TIO N
There are Mode according to SW position as
following Table 6-1.
According as port of fixed Micom is Low, the unit is
operating as following Table 6-1.
Table 6-1
POSITION MODE
OPEN
REMOCON
GND
EMERGENCY
Содержание DMB-1822LH
Страница 8: ...8 DMB 2122LH unit A 12000BTU h ...
Страница 41: ...41 6 WIRING DIAGRAM DMB 1822 1832LH ...
Страница 43: ...43 DMB 2112 2122LH ...
Страница 54: ...DMB 1822 2112 2122LH O utdoor 10 PC B DRIVING DESC RIPTION 1 P CB CI R CU I T D I A G R A M ...
Страница 55: ......
Страница 56: ...DMB 1822 2112 2122LH 9K indoor ...
Страница 57: ......
Страница 58: ...DMB 2112 2122LH 12K indoor ...
Страница 59: ......
Страница 82: ...79 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Страница 87: ...84 3 EX P LO D ED D I A G R A M I n d o o r U n it DMB 1822LH DMB 2112 2122LH unit B 9K ...
Страница 89: ...86 DMB 2112LH unit A 12K ...
Страница 92: ...89 DMB 2122LH unit A ...
Страница 95: ...92 4 EXPLODED DIAGRAM Outdoor Unit DMB 1822 1832LH 5 ...
Страница 97: ...DMB 2112 2122LH 94 ...
Страница 99: ...96 5 CONTROL BOX ASSEMBLY DMB 1822 1832LH DMB 2112 2122LH unit B 9K L N ...
Страница 101: ...98 DMB 2112LH unit A 12K ...
Страница 103: ...100 DSB 2122LH unit A 12K ...
Страница 105: ...102 6 CONTROL PANEL ASSEMBLY 7 j ...