INSTALLING THE AC CONNECTION WIRE TO THE INDOOR UNIT FOR AC POWER SUPPLY
The AC Connection wire is used to supply AC from the outdoor unit to the indoor units. To install AC connection wire,
follow the procedures below.
NOTE:
• This appliance must be installed according to National power supply requirement.
• If the supply cord is damaged, it must be replaced by the manufacuturer or its service agent or a similarly
qualified person in order to avoid a hazard.
• Make sure the outdoor unit’s AC cord is not connected to AC connection wire.
• When connecting wires, make sure they are fully inserted and minimum copper wire is exposed. If they are
not, shorting, overheating, no operation, etc. may occur.
• Be sure to comply with local codes on running a wire from the indoor to the outdoor unit.
1. Open the connection cover on the indoor unit to access
the connection area.
Remove the Connection Cover.
• Loosen the screw fixed at the Connection Cover.
• Remove the Connection Cover.
2. Fish the AC connection wire from the rear of the
indoor unit through the front of the unit.
For easier connection, make sure enough wire
is pulled through the front. Use the wire as
shown below:
3. To connect wires, loosen the screw in the
Terminal Block and insert the correct wires like
following figure.
Connect the Brown wire to the “L” connection,
Yellow/Green wire to the “
” connection and
the Blue wire to “N” connection.
Screw
Screw (Special screw)
Blue
Yellow/Green
Brown
L
N
Brown
Blue
Yellow/Green
Содержание DMB-1822LH
Страница 8: ...8 DMB 2122LH unit A 12000BTU h ...
Страница 41: ...41 6 WIRING DIAGRAM DMB 1822 1832LH ...
Страница 43: ...43 DMB 2112 2122LH ...
Страница 54: ...DMB 1822 2112 2122LH O utdoor 10 PC B DRIVING DESC RIPTION 1 P CB CI R CU I T D I A G R A M ...
Страница 55: ......
Страница 56: ...DMB 1822 2112 2122LH 9K indoor ...
Страница 57: ......
Страница 58: ...DMB 2112 2122LH 12K indoor ...
Страница 59: ......
Страница 82: ...79 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Страница 87: ...84 3 EX P LO D ED D I A G R A M I n d o o r U n it DMB 1822LH DMB 2112 2122LH unit B 9K ...
Страница 89: ...86 DMB 2112LH unit A 12K ...
Страница 92: ...89 DMB 2122LH unit A ...
Страница 95: ...92 4 EXPLODED DIAGRAM Outdoor Unit DMB 1822 1832LH 5 ...
Страница 97: ...DMB 2112 2122LH 94 ...
Страница 99: ...96 5 CONTROL BOX ASSEMBLY DMB 1822 1832LH DMB 2112 2122LH unit B 9K L N ...
Страница 101: ...98 DMB 2112LH unit A 12K ...
Страница 103: ...100 DSB 2122LH unit A 12K ...
Страница 105: ...102 6 CONTROL PANEL ASSEMBLY 7 j ...