background image

EN

The following manual is only a guide to assist you and is not a complete or comprehensive manual 
of ali aspects of maintaining and repairing your generator. The equipment you have purchas d is a 
complex piece of machinery. We recommend that you consult with a dealer if you have doubts or 
concerns as to your experience or ability to properly maintain or repair your equipment. You will 
save time and the inconvenience of having to go back to the store if you choose to write or call us 
concerning missing parts, service question ,operating ad vice, and/or assembly questions. 
Our air-cooled diese) generators have sorne of the following feature:

• Lightweight construction
• Air cooled
• Four-stroke diesel internal combustion engine
• Direct fuel injection system
• Recoil starter or an optional electric starter
• Large fuel tank
• Automatic voltage stabilizer
• NFB circuit protector
• AC and DC outputs
• Low oil pressure sensor

The air-cooled diese! generators are widely used when electrical power is scarce. Our generators 
provide a portable mobile solution in supplying power for field operations during project construc-
tion. Sorne other known applications include pipeline construction and metal welding when electri-
cal power is not available. 
This manual will explain how to operate and service your generator set. 
lf you have any questions or suggestions about this manual. please contact your local dealer or us 
directly. Consumers should notice that this manual might differ slightly from the actual product as 
more improvements are made to our products. Some of the pictures in this manual may differ slight-
ly Jrom the actual product as well. We reserves the right to make changes at any time without notice 
and without incurring any obligation.

1. TECHNICAL SPECIFICATIONS AND DATA

Engine Type: Single cylinder, Vertical, 4 Stroke, Direct injection, Air-cooled
Displacement: 418 cc
Max power: 5.5 kW
Rated power: 5.0 kW
Engine power: 10 hp / 3000 rpm
Speed: 3000 rpm
Bore×stroke: 86×72 mm
Fuel tank capacity: 13.5 L
Oil tank capacity: 1.65 L
Compression ratio: 19:01
Starting system:  Electric Start
Starting motor capacity: 12 V - 0.8 kW
Charging generator capacity: 12 V - 8.3 A
Battery capacity: 12 V - 30 Ah
Fuel consumption:  370 g/kW.h
Continuous running time: 5.5 hr
Noise level (7m): 77 dB(A)
Insulation grade: F

1-2 Basic parameters

1-2.1 Under the given conditions, the generator will output the specified power in the table listed 
below.
Table 1. The generator should output its rated power under these conditions 

  Height above sea level(in)   

Ambient temperature (F) 

 

Relative humidity (%)

 

 

 

    +60 

(+20 

°C) 

   60%

Table 2. The generator should output reliable work and its stipulated power

  Altitude height (in)    

 

Ambient temperature (F) 

 

Relative  humidity (%)

  < 39370.08 ( 1000m) 

 

41-104 (5-40 °C) 

 

 

90%

1-3 General dimensions and overview of the generators

1-3.1 General dimensions of the of the DDAEXE series generators

2

Содержание DDAE6000XE

Страница 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL DDAE6000XE Diesel generator...

Страница 2: ...INDEX 1 TECHNICAL SPECIFICATIONS AND DATA 3 2 OPERATING THE DIESEL GENERATOR 4 3 MAINTENANCE 14 4 TROUBLESHOOTING 17 5 PART LISTINGS 18 6 REMOTE CONTROL INSTRUCTIONS 23 WARRANTY 24 1...

Страница 3: ...r or an optional electric starter Large fuel tank Automatic voltage stabilizer NFB circuit protector AC and DC outputs Low oil pressure sensor The air cooled diese generators are widely used when elec...

Страница 4: ...mption 370 g kW h Continuous running time 5 5 hr Noise level 7m 77 dB A Insulation grade F 1 2 Basic parameters 1 2 1 Under the given conditions the generator will output the specified power in the ta...

Страница 5: ...t gases out 2 1 3 Prevention from accidental bums Never touch the muffler and its cover when the diesel engine is running Never touch the muffler and cover after the diesel engine has been used as the...

Страница 6: ...us to overfill the fuel tank Never exceed the red piston in the filter a After purchasing fuel put it into a drum and let it sit for 3 4 days b 3 4 days later insert half of the fuel sucker into the d...

Страница 7: ...ts in your engine such as bearings and other rotating part will shorten considerably Although there is an alarm system to check for low oil pressure it is always a good idea to check the amount of oil...

Страница 8: ...utterfly nut firmly 2 2 4 Checking the generator Note Only certain welder generator sets have an electric Jan incorporated on them Before starting the generator make ure the air switch is in the off p...

Страница 9: ...and tighten it 2 3 Checking the operation of the diesel engine 2 3 1 Low pressure alarm system The diese engines have a low pressure sensor system where if the oil pressure drops to low the sensor wil...

Страница 10: ...l engine is started remove your hand from the switch handle the switch will auto matically reset itself to the ON position 5 lf the engine is not starting after 10 seconds of cranking wait about 15 se...

Страница 11: ...up on surrounding parts resul ting in corrosion of these parts Note Avoid too much or to little of battery acid Check and fill it once a month if necessary 2 5 Procedures for starting the generator s...

Страница 12: ...11...

Страница 13: ...he specified parameters 2 7 2 Output of electricity 1 Raise the revolutions per minute turn the speed handle to the max setting of the generator to get the maximum power out of the generator lf not th...

Страница 14: ...ning 2 If the generator is not used for long periods of time the battery should be disconnected to avoid energy loss from the battery 3 Do not connect the negative and positive terminals of the batter...

Страница 15: ...e piston is on the compression stroke where the intake and exhaust val ves are closed What this does is prevent the engine from rusting when not in use 3 MAINTENANCE 3 1 Maintenance schedules Kepping...

Страница 16: ...anging the engine oil every 100 hours Take the oil cover out Remove the oil drain plug when the diesel engine is still hot Be careful of hot oil and hot engine as you may get bumed The bolt i located...

Страница 17: ...el filter form the port Use diesel fuel to clean the fuel filter Also remove the fuel injector and clean the carbon deposit around it The recommended time period for this is 3 months or 100 hours 3 1...

Страница 18: ...k the engine for 2 3 seconds To do this put the starter switch in the Start position Do not start the diesel engine 6 Finally pull the recoil starter until you feel resistance this is when the piston...

Страница 19: ...red 4 A detailed condition and time when the problem occurred in other words climate and atmosphe re 5 PART LISTINGS Overall view of engine generator assembly Number Part Description Quantity 1 Series...

Страница 20: ...ty 1 Left frame 1 2 Right frame 1 3 Board connected 4 4 Output panel bracket 1 5 Back board 1 6 Battery tray 1 7 Axle 2 8 Handrail 1 9 Carrier frame 1 10 Rubber mount 4 11 Washer 10 8 12 Spring washer...

Страница 21: ...Washer 10 1 29 Spring washer 10 1 30 Nut M10 1 31 Hexagon socket head cap screw 1 32 Spring washer 6 1 33 Steel tube 1 34 Nylon nut 6 1 35 Bolt 4 37 Flat washer M6 4 37 Shock absorber 4 38 Washer 6 4...

Страница 22: ...2 8 3 Prong socket 1 9 Current adjusting switch 1 10 Bolt 6 11 Electric panel bolt 6 12 Electric panel 1 13 Starter switch 1 14 Large nut 6 15 Oil alert lamp 1 16 Hour meter 1 17 Hour meter bolts 2 1...

Страница 23: ...1 8 Motor cover 1 9 Stator 1 10 Long bolt 4 11 Capacitar 1 12 Wiring Seat 1 13 M 5 x 15 Bolt 6 14 Stator Unit 1 15 Dust Cover 1 Fue system components Number Part Description Quantity 1 Fuel Cap 1 2 Se...

Страница 24: ...te control starting DO NOT USE THE STARTING SWITCH The generator will automatically start when you press the l key twice lf starting in cold weather please repeat this procedure several times NOTE lf...

Страница 25: ...r more nodes teaser on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation...

Страница 26: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea...