2. OPERATING THE DIESEL GENERATOR 

2-1 General main points of safety during operation of the generator set.

In order to operate the generator set safely ,please follow all the instructions provided in this manual 
carefully . Doing so otherwise may lead to accidents and or equipment damage. 

2-1.1 Fire prevention

The proper fuel for the diesel generator set is light diesel fuel . Do not use gasoline, kerosene and or 
other fuels other than light diesel fuel. Keep a11 flammable fuels away from the generator as the 
generator may spark and ignite these gases. In order to prevent fires from occurring and to provide 
enough ventilation for people and the machine ,keep the diesel generator at least l .5meters away 
from buildings and or other equipment.Always operate your diesel generator on a level site .If the 
generator is operated on an incline , the lubricating system within the engine will not perform well 
and may lead to failure of the engine. 

2-1.2 Prevention from inhaling exhaust gases

Never inhale exhaust gases emitted by the engine. The exhaust gases contain toxic carbon monoxi-
de.Never operate your generator in places with poor ventilation.ln order to operate this machinery 
indoors , a suitable ventilation system for the building is required to draw the poisonous exhaust 
gases out. 

2-1.3 Prevention from accidental bums

Never touch the muffler and its cover when the diesel engine is running .Never touch the muffler and 
cover after the diesel engine has been used ,as the muffler remains hot for a good period of time. 

2-1.4 Electric shock and short circuits

Never touch the generator if the generator is wet.Also never touch the generator if your hand is 
wet.Never operate your generator if the weather conditions call for any type of precipitation such as 
rain ,snow or fog .To prevent electrical shocks,the generator should be grounded. U se a lead to 
connect the grounding end of the generator to the grounding surface of choice. Please refer to 
Fig.2-1 and Fig .2-2 before beginning to use the electric generator. 

NOTE: 

When connecting devices to the generator, make sure all other devices are rated lower than 

the generators output. Any generator socket should not be overloaded over its regulated limit.

2-1.5 Other safety points

Before operating this generator, ali operators should have a good knowledge of how to break the 
circuit if any accidents occur. Also, all operators should be familiar with ali the switches and func-
tions of the generator before using this machine. While operating the generator, wear safe shoes 
and suitable clothes during operation. Always keep children and animals away from the generator. 

2-1.6 Battery

The electrolytic liquid of the battery also known as battery acid contains sulfuric acid. In order to 

protect your eyes,skin and clothing, wear protective gear when working with the battery. If you 
come in contact with the electrolytic liquid, wash it immediately with clean water. Also, if the elec-
trolytic liquid comes in contact with your eyes, see a doctor immediately. 

2-2 Preparation before operation
2-2.1 Fuel choices and fuel treatment

Fuel tank 

Use only light diesel fuel. The fuel should be filtered clean. Never let dust and water mix with fuel in 
the fuel tank. Otherwise it will clog the fuel lines and oil nozzles. It may also damage your pressure 
pump. Note: It is dangerous to overfill the fuel tank. Never exceed the red piston in the filter. 

a. After purchasing fuel, put it into a drum and let it sit for 3-4 days.
b. 3-4 days later, insert half of the fuel sucker into the drum (water and impurities stay in the lower 
portion of the drum).

Air filter element

Do not wash the air filter. The element is made of dry material, which does not permit washing. 
When the output of the diesel engine is bad or the color of the exhaust gas is abnormal, replace the 
air filter element. Never start the diesel engine without the air filter.

NOTE: 

Never smoke near the opening of the fuel tank. Do not let sparks get near the fuel or fuel tank 

and do not overfill tank. After filling, tighten the fuel cap.

2-2.2 Filling engine oil

Pouring inlet of lubricating oil 
Put the generator set at level state, Fill the lubricating oil to it till the inlet. At the same time. Check 
the oil level with dipstick. It is neecessary only to insert the dipstick lightly. Caution: Don 't ratate the

A.P.I

Classification of maintenance for diesel engine. The lubricating oíl should be CC or CD grade. 

Engine oil is the most important factor in deterrnining the life of your generator engine. If you use 
poor engine oil or if you don't change the oil regularly,the piston and cylinder will wear easily or 
seize up. Also,the life of the other parts in your engine such as bearings, and other rotating part will 
shorten considerably.

Although there is an alarm system to check for low oil pressure, it is always a good idea to check 
the amount of oil inside the engine .If the oil leve! is low ,fill it before tarting the engine. A good time 
to drain the oil from the engine is when the diesel engine is still hot. If the engine is fully cooled, it is 
more difficult to drain all the oil out or sorne impurities will remain in the engine.

WARNING:

 Don't fill engine oil when diesel is operating.

2-2.3 Check the air filter
(1)Loosen the butterfly nut, take the cover of the air filter off and take the air filter element out.

Do not use detergent to wash the air filter element. When the performance of the engine decreases 
or when the color of the exhaust gases is bad, exchange the filter element.Never start the engine 
without the air filter as foreign objects may enter the intake and damage the engine.

(2)After replacing the air filler element, replace the cover and tighten the butterfly nut firmly.

2-2.4 Checking the generator

(Note:Only certain welder generator sets have an electric Jan incorporated on them.)
Before starting the generator,make ure the air switch is in the "off" position .Starting the generator
with the switch in the "on" switch is very dangerous.

The generator should be grounded in order to prevent electric shock.

Use dry compressed air(with pressure about 1. (96 x 105 Pa )to blow the dust out in the electric
control cabinet and at the surface of the generator. Check to see how clean the surface
of the sliding ring is. Check the pressure of the carbon brush.Also,check whether the position

10

of the carbon brush at the slide rig is correct and the fixture is reliable with a good contact.

According to the electric wiring diagram, check to see whether the connecting wire is correct and 
the connected place is firm.

Use a 500 M

 meter to measure the insulation resistance of the electrical part. The resistance

should be no less than 5 M

. When measuring devices ,make sure the capacitor is turned off.

Otherwise, it will bum the capacitor. (For the low noise set,the inspection may not be performed).

2-2.5 The fuel and oíl in a new engine is drained before sold.

Before you start the engine, please fill the fuel tank and engine oíl first.Then,check to see if there are 
air bubbles in the engine. lf there are, follow these procedures.Loosen the connecting nut between 
the oil injection pump and oil pipe. Bleed the air from the system until there are no more bubbles. 
Then replace the connecting nut and tighten it.

2-3 Checking the operation of the diesel engine 
2-3.1 Low-pressure alarm system.

The diese) engines have a low-pressure sensor system where if the oil pressure drops to low, the 
sensor will shut the engine off. The purpose of having this system is to ensure that the engine does 
not seize up. If there is not enough oil in the engine,the temperature of the oil will be raised too high. 
On the contrary, if there is too much oil in the engine, the engine oil can slow the engine down 
considerably.

2-3.2 Engine break in

When you purchase a brand new engine, the engine must be properly broken in. The break in period 
is about 20 hours. (1 )Avoid overloading the engine when brand new. 
(2) Change the engine oil according to specifications.An oíl change for a brand new engine is about 
20 hours or every month,an older engine,the oil change is about 100 hours or three months. 

2-4 Starting the generator set
2-4. 1 Manual starting.

Start the engine in accordance with procedures below: (1) Put the fuel switch in the "ON" position. 

(2) Turn the handle of the engine to the "RUN" position.

(3) Pull the recoil starter handle out until you feel resistance. lt will reset to its original position 
automatically. The handle should be reset into its recoil device slowly to prolong the life of the life
of the engine starter.
(4) In cold clima te, it is difficult to start the engine. To remedy this, pull the rubber plug out from the 
rocker of the diese) engine and fill 2 ml of engine oíl. Before starting, put the rubber plug back in 
place. If you don 't put the rubber plug back in place, rain, dust and other dirt can enter into the 
diesel engine. It will cause the parts inside the diesel engine to wear quickly and lead to engine 
failure. 

2-4.2 Electric starting

The procedures for preparing to start eh engine are the same as the manual starting engine.

2-4.3 Battery

1. Insert key into ignition and put it in the "off' position.
2. Put the speed handle in the “RUN” position.
3. Tum the start switch clockwise to the "START" position; To set the silent type, first turn it clockwi-
se to the "RUN" (ON) position for 1-2 seconds. The electromagnetic iron will be triggered, now tum it 
clockwise to the "START" position.
4. After the diesel engine is started, remove your hand from the switch handle; the switch will auto-
matically reset itself to the "ON" position.
5. lf the engine is not starting after 10 seconds of cranking, wait about 15 seconds before trying it 
again. If you crank to long, the voltage of the battery will drop. This can lead to improper ignition. 
When the diesel engine is operating, let the ignition retain on the 'ON"position.

NOTE:

 If you crank the starter to long, the battery may be drained too much to provide enough 

energy for proper engine ignition. Also, when the diesel engine is operating, Let the key retain in the 
"ON" position.

IMPORTANT NOTICE:

 Ali of our units come with a dry battery for shipping safety purposes.

In order to get your generator started for the first time; the battery must be filed with battery acid 
which can be purchased at a local automotive supply store and slowly charged (trickle charged) for 
a day. After charging, the battery may be used. To proerly maintain you battery; check the height of 
the battery acid once a month. If the level of the liquid drops too low, fill it with distilled water until it 
reaches the high mark. If there is not enough battery acid, then the diesel engine cannot be started. 
lt is important to keep the liquid level between the high and low limits.

lf the leve] in the battery is too high, the liquid may flow out and end up on surrounding parts resul-
ting in corrosion of these parts. Note: Avoid too much or to little of battery acid. Check and fill it 
once a month if necessary. 

2-5 Procedures for starting the generator set

This procedure applies to the DDAEXE series recoil starting style models.

Содержание DDAE6000XE

Страница 1: ...Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com USER S MANUAL DDAE6000XE Diesel generator...

Страница 2: ...INDEX 1 TECHNICAL SPECIFICATIONS AND DATA 3 2 OPERATING THE DIESEL GENERATOR 4 3 MAINTENANCE 14 4 TROUBLESHOOTING 17 5 PART LISTINGS 18 6 REMOTE CONTROL INSTRUCTIONS 23 WARRANTY 24 1...

Страница 3: ...r or an optional electric starter Large fuel tank Automatic voltage stabilizer NFB circuit protector AC and DC outputs Low oil pressure sensor The air cooled diese generators are widely used when elec...

Страница 4: ...mption 370 g kW h Continuous running time 5 5 hr Noise level 7m 77 dB A Insulation grade F 1 2 Basic parameters 1 2 1 Under the given conditions the generator will output the specified power in the ta...

Страница 5: ...t gases out 2 1 3 Prevention from accidental bums Never touch the muffler and its cover when the diesel engine is running Never touch the muffler and cover after the diesel engine has been used as the...

Страница 6: ...us to overfill the fuel tank Never exceed the red piston in the filter a After purchasing fuel put it into a drum and let it sit for 3 4 days b 3 4 days later insert half of the fuel sucker into the d...

Страница 7: ...ts in your engine such as bearings and other rotating part will shorten considerably Although there is an alarm system to check for low oil pressure it is always a good idea to check the amount of oil...

Страница 8: ...utterfly nut firmly 2 2 4 Checking the generator Note Only certain welder generator sets have an electric Jan incorporated on them Before starting the generator make ure the air switch is in the off p...

Страница 9: ...and tighten it 2 3 Checking the operation of the diesel engine 2 3 1 Low pressure alarm system The diese engines have a low pressure sensor system where if the oil pressure drops to low the sensor wil...

Страница 10: ...l engine is started remove your hand from the switch handle the switch will auto matically reset itself to the ON position 5 lf the engine is not starting after 10 seconds of cranking wait about 15 se...

Страница 11: ...up on surrounding parts resul ting in corrosion of these parts Note Avoid too much or to little of battery acid Check and fill it once a month if necessary 2 5 Procedures for starting the generator s...

Страница 12: ...11...

Страница 13: ...he specified parameters 2 7 2 Output of electricity 1 Raise the revolutions per minute turn the speed handle to the max setting of the generator to get the maximum power out of the generator lf not th...

Страница 14: ...ning 2 If the generator is not used for long periods of time the battery should be disconnected to avoid energy loss from the battery 3 Do not connect the negative and positive terminals of the batter...

Страница 15: ...e piston is on the compression stroke where the intake and exhaust val ves are closed What this does is prevent the engine from rusting when not in use 3 MAINTENANCE 3 1 Maintenance schedules Kepping...

Страница 16: ...anging the engine oil every 100 hours Take the oil cover out Remove the oil drain plug when the diesel engine is still hot Be careful of hot oil and hot engine as you may get bumed The bolt i located...

Страница 17: ...el filter form the port Use diesel fuel to clean the fuel filter Also remove the fuel injector and clean the carbon deposit around it The recommended time period for this is 3 months or 100 hours 3 1...

Страница 18: ...k the engine for 2 3 seconds To do this put the starter switch in the Start position Do not start the diesel engine 6 Finally pull the recoil starter until you feel resistance this is when the piston...

Страница 19: ...red 4 A detailed condition and time when the problem occurred in other words climate and atmosphe re 5 PART LISTINGS Overall view of engine generator assembly Number Part Description Quantity 1 Series...

Страница 20: ...ty 1 Left frame 1 2 Right frame 1 3 Board connected 4 4 Output panel bracket 1 5 Back board 1 6 Battery tray 1 7 Axle 2 8 Handrail 1 9 Carrier frame 1 10 Rubber mount 4 11 Washer 10 8 12 Spring washer...

Страница 21: ...Washer 10 1 29 Spring washer 10 1 30 Nut M10 1 31 Hexagon socket head cap screw 1 32 Spring washer 6 1 33 Steel tube 1 34 Nylon nut 6 1 35 Bolt 4 37 Flat washer M6 4 37 Shock absorber 4 38 Washer 6 4...

Страница 22: ...2 8 3 Prong socket 1 9 Current adjusting switch 1 10 Bolt 6 11 Electric panel bolt 6 12 Electric panel 1 13 Starter switch 1 14 Large nut 6 15 Oil alert lamp 1 16 Hour meter 1 17 Hour meter bolts 2 1...

Страница 23: ...1 8 Motor cover 1 9 Stator 1 10 Long bolt 4 11 Capacitar 1 12 Wiring Seat 1 13 M 5 x 15 Bolt 6 14 Stator Unit 1 15 Dust Cover 1 Fue system components Number Part Description Quantity 1 Fuel Cap 1 2 Se...

Страница 24: ...te control starting DO NOT USE THE STARTING SWITCH The generator will automatically start when you press the l key twice lf starting in cold weather please repeat this procedure several times NOTE lf...

Страница 25: ...r more nodes teaser on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation...

Страница 26: ...www daewoopowerproducts com Manufactured under license of Daewoo International Corporation Korea...