manualshive.com logo in svg
background image

DAMAX 15/30

 Cargador de batería / Battery charger 

Fabricado bajo licencia de 

Daewoo International Corporation

, Corea

Manufactured under license of 

Daewoo International Corporation

, Korea

www.daewoopowerproducts.com

MANUAL DE USO/USER’S MANUAL

Содержание DAMAX 15

Страница 1: ...r de bater a Battery charger Fabricado bajo licencia de Daewoo International Corporation Corea Manufactured under license of Daewoo International Corporation Korea www daewoopowerproducts com MANUAL D...

Страница 2: ...Especificaciones 6 Normas de seguridad 7 Instalaci n 8 Conexi n a la red el ctrica 9 Mantenimiento 10 Garant a 7 6 6 6 6 7 7 8 8 10 INDEX 1 Introduction 2 Descripction 3 Electrical circuit 4 Outline...

Страница 3: ...o esta protecci n t rmica se activa con el sobre calentamiento de la unidad La unidad funcionar con dicha protecci n hasta que la temperatura vuelva a la normalidad El dispositivo est equipado con un...

Страница 4: ...s cables de alimentaci n y aseg rese de que el aislamiento no est da ado No utilice el cargador ni los cables de suministro de energ a que tienen poca secci n transversal Si los cables est n sobrecale...

Страница 5: ...de salida corriente a Compruebe si el interruptor est en correcta posici n 12V 24V b Compruebe si los ajustes no han cambiado por sobrecalentamiento o sobrecarga c Corrobore el fusible d Si despu s d...

Страница 6: ...mario sobre la superficie del cilindro y el pist n y la destrucci n de los anillos de pist n Adem s la garant a no cubre fallas de reguladores de energ a de tensi n autom ticos debido a la operaci n i...

Страница 7: ...e the unit To do this thermal protection is activated with the overheating of the unit The unit will operate with this protection until the temperature returns to normal The device is equi pped with a...

Страница 8: ...re the insulation is not damaged Do not use the charger or power supply cables with little cross section If the cables are overheated stop charging to prevent rapid deterioration of the insulation Nev...

Страница 9: ...alue on the ammeter 5 User actions in the absence of the output voltage current a Check if the switch is properly set 12V 24V b Check the settings have not changed from overheating or overloading c Co...

Страница 10: ...Road Longquanyi Chengdu 610100 P R China Notified body Ente Certificazione Machine Srl Number of notified body 1282 and conforms to the standard EN 60335 1 2012 A11 2014 AC 2014 EN 60335 2 29 2004 A2...

Страница 11: ...er on the surfaces of the cylinder and the piston or destruction of piston rings Also the warranty does not cover failure of the automatic voltage regulator due to incorrect operation Failure caused b...

Страница 12: ...www daewoopowerproducts com Fabricado bajo licencia de Daewoo International Corporation Corea Manufactured under license of Daewoo International Corporation Korea...

Отзывы: