3-2. DOOR S/W
1) DOOR S/W
1
Locking of Door
A pulse of 20m sec duty is transmitted twice to the solenoid 3 seconds after the bimetal door switch starts
running until the door is locked. The bimetal starts running as soon as the power button is pressed.
2
Unlocking of Door
A pulse of 20m sec duty is transmitted to the solenoid after the bimetal door switch is turned off until the
door is unlocked
3
The wash cycle is startable as the motor and other parts become available for operation when the door is
locked.
4
The door is locked when the water is measured at 61°C or hotter or the water level is above the safety level
after the Power button is turned on.
5
The door is unlocked promptly after the cycle is complete.
6
The door is unlocked if it is openable when the cycle is suspended.
3-3. Child Lock
1) Mechanism
1
If the 'Program' and 'Add Rinse' buttons are pressed simultaneously, the Child Lock mode starts running.
2
In the Child Lock mode, all buttons except the Power button (press it for over 1.5 seconds) are unavailable
for use.
3
The Child Lock mode is terminated if the 'Program' and 'Add Rinse' buttons are pressed simultaneously.
4
If the Power button is pressed for over 1.5 seconds, the Child Lock mode is terminated.