37
1) Specification
2) Operation
If the power supply is connected to the water inlet valve, the rod valve is drawn by the coil's magnetic field to
open the diaphragm hall and push up the diaphragm with water pressure. This leads to open the water flow and
start the water supply. If the power supply is cut off, the coil's magnetic field disappears and the force of internal
spring leads the rod valve to close the diaphragm hall, leading to block the water flow.
3. Specifications, Operation, and Defect Inspection of Inlet Valve [Valve for cold water and softener]
Type
1/4 Inch Fitting Solenoid Valve
Voltage
AC 220 VOLT 50/6Ohz
Electric Current
30mA or lower
Rating Time
60 minutes (Unloaded = 40 minutes)
Power Consumption 5.5W or lower
Terminal Angle
180 degrees (Clockwise at water inlet)
Fluid in Use
Tap water
Flux (4kgf/cm2)
7L or more
Fluid Pressure
0.2 - 8kgf/cm2
Opening and Closing Speed
1.0 sec or shorter
Max. Temperature 60°C or lower
Coil Resistance
4.31k_± 5% (20°C)
Diaphragm Opreation 2.0mm or more
Category
Specifications
Configuration
Water inlet
#250
Red color
(Water inlet)
SUS
Filter