66
(Type B : Seesaw type control
panel)
Cooling
Ү
First start engine and set the room
temperature with the control knob.
Ү
Push the cooling/vent switch to
“cooling” side.
Ү
Push “ON” the power switch, the all
systems like the compressor, con-
denser fan and evaporator blower
start operation for cooling.
(The “cooling” indicating lamp
comes on).
Ү
When the room temperature drops
below the set temperature, the sys-
tem does air blowing operattion
only, and the room temperature
rises beyond the set temperature,
the system returns to cooling oper-
ation automatically.
Ventilation
Ү
Push the cooling/vent switch to
“VENT” side.
Ү
Push “ON” the power switch, to
maintain adequate room tempera-
ture by blowing in the fresh and
cool outdoor air.
Ү
At this time the compressor and
condenser fan do not operate, but
the blowers in the evaporator oper-
ate.
Stop
Ү
Normal stopping
First push “cooling/vent” switch to
“vent” side, then cooling stops and
the system operates only for venti-
lation, Push power switch “OFF”,
then all systems stop operation.
Ү
Emergency self stopping.
- When refrigerant pressure rises
abnormally high (over 22kg/cm
2
),
the electric clutch of compressor is
disengaged, so the compressor
stops working.
(The “Trouble” indicating lamp
comes on).
In the case that any troubles are
checked in operation, the emer-
gency self stop occurs, this means
the stop of compressor, the con-
denser and evaporator fan do not
stop and continue operating.
AIR-CONDITIONER
VENT
COOLING
COOLING
ON
OFF
VENT
HIGH
LOW
TEMP
TROUBLE
15
30
Содержание BM090
Страница 122: ...120 EARPHONE OPTION 1 Volume controllor 2 Select the media Tape 1 Tape 2 Radio TV VTR 3 Earphone jack 3 2 1...
Страница 214: ...212 1 Cover RR fuse box 2 Bracket Rr fuse box 3 Regulator Assembly 4 18P Fuse box Rear fuse box 1 3 4 2...
Страница 220: ...218 Drag link RR 2 points For leaf spring Spring and shackle pin 12 points...
Страница 255: ...253 BODY DIMENSION BM090 ROOF ON COOLER NON COOLER APPROX APPROX...
Страница 256: ...254 BS090...
Страница 257: ...255 1853 1853 3225 3225 2490 2490 2050 2050 35 35 1975 1975 4200 4200 8990 8990 2750 2750 30 30 BH090...
Страница 258: ...256 ROOF ON COOLER SUB ENG COOLER NON COOLER 2050 2100 70 70 3110 5200 10550 1853 2490 3225 APPROX 3110 APPROX BS106...
Страница 259: ...257 ROOF ON COOLER SUB ENG COOLER NON COOLER APPROX APPROX BH115E...
Страница 260: ...258 ROOF ON COOLER SUB ENG COOLER APPROX APPROX BH120E...