81
PRINTED CIRCUIT BOARD <KOG-374R0S, KOG-375R0S>
1. CIRCUIT CHECK PROCEDURE
1. Low Voltage Transformer check
• The low voltage transformer is located on the P.C.B.
• Measuring condition: input voltage : 230V/Frequency : 50Hz
2. Voltage check
• Key check point
• Check method
NO
CHECK POINT
REMARK
1
IC 1 PIN 2, 21, 30, 34
–5 VDC
2
IC 1 PIN 35
3
IC 1 PIN 31 OR 32
NOTE :
Each measure point must be measured with GND points.
NOTE :
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
0V
T
—5V
Terminal Voltage
4-7
LOAD
AC 25.8 V
NO LOAD
AC 28.4 V
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC -5V±0.25V
Replace VL1, EC1
NO LOAD
2
MP2
DC -12V±2.0V
Replace EC2, D6, D11, D12
NO LOAD
T:20ms(50Hz)
T:250 ns(4MHz)
Содержание KOG-371G0S
Страница 7: ...6 4 KOG 371R0S KOG 391R0S 465 495 279 294 360 388 5 KOG 374R0S 465 279 360 6 KOG 375R0S 465 279 360...
Страница 8: ...7 7 KOG 86AH7S 86AH7P 90AH 495 294 394...
Страница 63: ...62 2 KOG 396T1S...
Страница 65: ...64 Mesurement point...
Страница 67: ...66 2 P C B CIRCUIT DIAGRAM...
Страница 71: ...70 Mesurement point...
Страница 73: ...72 2 P C B CIRCUIT DIAGRAM...
Страница 77: ...76 Mesurement point...
Страница 79: ...78 2 P C B CIRCUIT DIAGRAM...
Страница 83: ...82 Mesurement point...
Страница 85: ...84 2 P C B CIRCUIT DIAGRAM...
Страница 88: ...87 Mesurement point...
Страница 90: ...89 2 P C B CIRCUIT DIAGRAM...
Страница 101: ...100 2 KOG 396T1S 2 KOG 396T1S...