55
TROUBLE SHOOTING GUIDE
CONDITION
CHECK
Check continuity of magnetron
Defective
magnetron
RESULT
No
Continuity
CAUSE
REMEDY
Replace
Outlet has
proper
voltage Fuse
does not
blow.
CONDITION
CHECK
Check continuity of primary
interlock switch
Malfunction of
primary interlock
switch
RESULT
No
Continuity
CAUSE
REMEDY
Adjust or
replace
Turn table
motor and
oven lamp
do not turn
on
Check continuity of secondary
interlock and D.O.M. switches
Malfunction of
primary interlock
and D.O.M.
switch
No
Continuity
Adjust or
replace
Check D.C. voltage being
supplied to RELAY (RY2) coil
Defective touch
control circuit
0 V
Replace
Faulty contacts of
RELAY (RY2) or
open relay coil
Approx.
15 VDC
Replace
Check continuity of
noise filter board
Defective line
filter board
No
Continuity
Replace
Check continuity of
power supply cord
Open power
supply cord
No
Continuity
Replace
Defective touch
control circuit
Normal
Replace
NOTE
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.
(TROUBLE 2)
Display shows all figures selected, but oven does not start cooking, even though desired program and
time are set and start pad is tapped.
Содержание KOG-371G0S
Страница 7: ...6 4 KOG 371R0S KOG 391R0S 465 495 279 294 360 388 5 KOG 374R0S 465 279 360 6 KOG 375R0S 465 279 360...
Страница 8: ...7 7 KOG 86AH7S 86AH7P 90AH 495 294 394...
Страница 63: ...62 2 KOG 396T1S...
Страница 65: ...64 Mesurement point...
Страница 67: ...66 2 P C B CIRCUIT DIAGRAM...
Страница 71: ...70 Mesurement point...
Страница 73: ...72 2 P C B CIRCUIT DIAGRAM...
Страница 77: ...76 Mesurement point...
Страница 79: ...78 2 P C B CIRCUIT DIAGRAM...
Страница 83: ...82 Mesurement point...
Страница 85: ...84 2 P C B CIRCUIT DIAGRAM...
Страница 88: ...87 Mesurement point...
Страница 90: ...89 2 P C B CIRCUIT DIAGRAM...
Страница 101: ...100 2 KOG 396T1S 2 KOG 396T1S...