56
CONDITION
CHECK
Check continuity of high
voltage fuse
RESULT
No
Continuity
Check continuity if high
voltage capacitor terminals
with wires removed
Replace high voltage fuse
Continuity
CAUSE
Defective high
voltage
transformer
REMEDY
Replace
No
microwave
oscillation
Check continuity of high voltage
rectifier in forward and backward
direction with DC megger
Continuity in
backward
direction
Defective high
voltage rectifier
Replace
Connect megger leads to
magnetron terminal and
magnetron body
Continuity
Defective
magnetron
Replace
Check resistance of primary and
secondary coil of high voltage
transformer
0
Ω
or
∞
Defective high
voltage
transformer
Replace
Check continuity of magnetron
with wires removed
No
Continuity
Defective
magnetron
Replace
Check continuity of filament
terminal of high voltage
transformer
No
Continuity
Defective high
voltage
transformer
Replace
Check D.C. voltage being
supplied to RELAY (RY1) coil
0 V
Defective touch
control circuit
Replace
Approx
15 VDC
Faulty
contacts or
RELAY (RY1)
or open
relay coil
Replace
(TROUBLE 3)
No microwave oscillation even though fan motor rotates.
Содержание KOG-371G0S
Страница 7: ...6 4 KOG 371R0S KOG 391R0S 465 495 279 294 360 388 5 KOG 374R0S 465 279 360 6 KOG 375R0S 465 279 360...
Страница 8: ...7 7 KOG 86AH7S 86AH7P 90AH 495 294 394...
Страница 63: ...62 2 KOG 396T1S...
Страница 65: ...64 Mesurement point...
Страница 67: ...66 2 P C B CIRCUIT DIAGRAM...
Страница 71: ...70 Mesurement point...
Страница 73: ...72 2 P C B CIRCUIT DIAGRAM...
Страница 77: ...76 Mesurement point...
Страница 79: ...78 2 P C B CIRCUIT DIAGRAM...
Страница 83: ...82 Mesurement point...
Страница 85: ...84 2 P C B CIRCUIT DIAGRAM...
Страница 88: ...87 Mesurement point...
Страница 90: ...89 2 P C B CIRCUIT DIAGRAM...
Страница 101: ...100 2 KOG 396T1S 2 KOG 396T1S...