8
Cleaning and maintaining the appliance
Other notices
During power cut:
1. Open the appliance door as briefly as possible.
2. Do not put new food to avoid temperature increases inside compartments.
Notices power cut in advance:
1. Set the temperature control at position COLD for low temperature inside compartments.
2. Make some ice cubes and put into the top of the refrigerator compartment.
9
Non-fault instances and special instances
Non-fault instances
Sounds like buzz
The compressor makes buzz sounds when working.
If the feet are not adjusted on vertical and stable position, there are shocks
and noises. Adjust the feet on vertical and stable position.
Long time starting
In summer, the ambient temperature is high. It is normal that the compressor
starts frequently.
Higher power consumption than the rating parameter
The rating parameter is from the test. Test condition are on 25
ambient
temperature, 5
in the refrigerator compartment, -18
in the freezer
compartment, without opening the doors and keeping working 24hours.
If with more food inside, on a higher ambient temperature or open the
doors frequently, the actual power consumption is higher.
Special instances
Instances Possible reasons Handlings
No cooling
The plug is not inserted properly Check the plug
The fuse is switched off Check the fuse
There is a power cut Please check if power is on
The temperature Open the doors in a long time Close the doors
in the compartments Put too many food inside
Put food less than the
is high appliance capacity
The thermostat control is not Adjust the thermostat control
proper or the ambient
temperature is high
There are humidity The outlet hole for frost water Clean the outlet hole for frost
or water inside the is blocked off. Water
refrigerator
compartment
Frost on the outer surface of the appliance
High humidity in air caused this. Just wipe off frost.
Frost in the back of the refrigerator compartment
The refrigerant tube close the back of the refrigerator compartment and
the temperature nearby is lower and cause frost.
Automatic defrost is processed after the refrigerator compartment stops
working.
High temperature on the door frame of the freezer compartment
It is a special measure to prevent icing around the door.
High temperature at the lateral sides
The condenser is inside the upper surface of the lateral sides. The condenser
emits heat when the appliance works.
In summer, the lateral temperature is around 50 .
High temperature on the compressor
When the appliance works, the temperature on the compressor is about 80 .
Sounds like water current in the appliance
The refrigerant goes through the refrigerant tube when the appliance works.
Sounds like click in the appliance
There are shrinkage and expanding between inside body and the refrigerant
tube.
The compressor can not start
The voltage is too low.
Recommend to fit one voltage regulator which power capacity is 500W higher.
Non-fault instances and special instances
Replace lamp
Cut-off power ,disassemble lamp-chimney ,use hand to disassemble lamp .
Contra rotate the lamp ,then take out the lamp.
Clockwise circumvolve new lamp into the lamp holder. (Specification of lamp :should
not more than 10W screw-base lamp.)
Содержание Daema FR-208
Страница 7: ......