Troubleshooting
Problem
Cause
Action
Pump's ca-
pacity is too
low
1. Wrong pump rotation (if no built in supply control relay)
2. Pump not enough submersed
3. Total head of application does't match pump performance
4. Impeller not rotating free
5. Delivery hose is squeezed
6. Strainer is blocked
7. Impeller is worn
1. Correct the phase sequence by shifting two out of three phases and start the pump again
2. Lower pump level or increase water level
3. Adjust pump performance or change to another pump
4. Clean system or adjust impeller properly
5. Straighten delivery hose
6. Clean strainer
7. Retrim or replace impeller
Pump
doesn't start
1. Wrong phase sequence (with built in supply control relay)
2. Fuse blown or circuit breaker tripped
3. Damaged cable
4. Power failure
5. Impeller not rotating free
6. Float switch is defective or not adjusted correctly
7. Failure of thermal switch
1. Shift two out of three phases and start the pump again
2. Measure stator and pump cable, replace if damaged
Check electric system for moisture or water ingress, replace seals if necessary
Check cable for damaged jacket
3. Replace cable, use new cable seal
4. Restore power supply
5. Clean system or adjust impeller properly
6. Check float switch adjustment
7. Identify failed thermal switch and bypass it according to separate section in this AIB
1
6
Содержание Sonora S330
Страница 1: ...Instruction Manual Sonora S330 ...
Страница 2: ...Original instructions Printed matter N 2954 8980 01 04 2019 ...
Страница 20: ...WIRING DIAGRAM 1 phase stator 20 ...
Страница 21: ...6 lead stator contactor 21 ...
Страница 22: ...9 lead stator contactor 22 ...
Страница 23: ...12 lead stator contactor 23 ...
Страница 24: ...6 lead stator terminal board 9 lead stator terminal board 24 ...
Страница 25: ...12 lead stator terminal board 25 ...