Set Authorization Mode
✦
CC1000 Address 1
✦
LT address 1, DO 1
➡
Register Address = (1 + 95) x 8 + (1 - 1) = 768
➡
RH = 768 div 256 = 3
➡
RL = 768 mod 256 = 0
✦
Set Authorization Mode to Forced On
➡
DL = 4
Query
CC1000
Address
Function
Code
Register Address
Register Address
Number of Registers
Number of Registers
Byte
Count
Write Data
Write Data
CRC
CRC
CC1000
Address
Function
Code
high (RH)
low (RL)
high
low
Byte
Count
high (DH)
low (DL)
low
high
1
16
3
0
0
1
2
0
4
148
147
Reply
CC1000
Address
Function
Code
Register Address
Register Address
Number of Registers
Number of Registers
CRC
CRC
CC1000
Address
Function
Code
high (RH)
low (RL)
high
low
low
high
1
16
3
0
0
1
1
141
CC1000 Modbus Reference 2.10e
!