background image

“A”

“B”

“A”

“B”

“D”

1“ (25mm) Min.

Clear to Top of

Door for Heat

Exhaust

31 1/4” (794mm)

Recommended

(May be Altered)

4“ Typical Toe Kick (Shown)

3/4” (19mm)

Support Platform

3/4” (19mm)

Support Platform

4“ (102mm) Min.

Between Cutout

Recommended 

Electrical 

Location

Recommended 

Electrical 

Location

Alternate 

Electrical 

Location

Alternate 

Electrical 

Location

1“ (25mm) Min.

Clear to Top of

Door for Heat

Exhaust

Single wall Oven

Side by Side

Cutout dimensions

36”

(914mm)

1 1/2”

(38mm)

Typical Counter

“A”

“B”

1“ (25mm) Min.

to Combustible Floor

4“ Typical Toe Kick (Shown)

Recommended

Electrical 

Location

3/4” (19mm)

Support Platform

1“ (25mm) Min. to Combustibles

1” (25mm) Min.

to Combustible Floor

“A”

“B”

“A”

“B”

1 1/2” (38mm)

Typical Counter

36” (914mm)

4“ Typical Toe Kick (Shown)

Alternate

Electrical 

Locations

3/4” (19mm)

Support Platform

4“ (102mm) Min.

Between Cutout

3/4” (19mm)

Support Platform

Recommended Electrical Location

1“ (25mm) Min. to Combustibles

Single wall Oven

Installed Under-Counter

Cutout dimensions

Single wall Oven

Side by Side

Installed Under-Counter

Cutout dimensions

Содержание Wall Oven

Страница 1: ...age 5 STEP 4 Electrical power supply requirements Page 5 STEP 5 Removing the oven door s Page 5 6 STEP 6 Turning of the power supply Page 6 STEP 7 Electrical connection Page 6 STEP 8 Mounting the oven...

Страница 2: ...the hinge catches with the door removed from the oven The hinge springs could release causing personal injury 2 Do not lift or carry oven door by the door handle WARNING DO NOT use handle as a grippi...

Страница 3: ...ess otherwise noted Be certain that proper clearance is provided for the oven door when it is in the open position The specified minimum cabinet depth and width must be provided The cabinet depth and...

Страница 4: ...Heat Exhaust Cabinet Preparation Model Number Cutout Height A Cutout Width B Min Cabinet Width C Min Cabinet Width D EO127 27 3 8 695mm 25 1 2 648mm 27 686mm 56 1 2 1435mm PO127 MOV127 MOH127 EO130 2...

Страница 5: ...de Cutout Dimensions 36 914mm 1 1 2 38mm Typical Counter A B 1 25mm Min to Combustible Floor 4 Typical Toe Kick Shown Recommended Electrical Location 3 4 19mm Support Platform 1 25mm Min to Combustibl...

Страница 6: ...imum supply wire size must comply with the National Electric Code ANSI NFPA 70 latest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Asso...

Страница 7: ...ack appliance wire to the black L1 power supply wire in the junction box 4 Connect the red appliance wire to the red L2 power supply wire in the junction box 5 Connect the green appliance wire to the...

Страница 8: ...il the door hinges are aligned with the openings in the oven frame Holding the door at about a 60 angle from the horizontal slide the hinges into the openings until the bottom hinge arms drop fully in...

Страница 9: ...nual Wait for the oven to heat to the jump in temperature noteS If the oven does not operate properly follow these troubleshooting steps 1 Verify that power is being supplied to the oven 2 Check the e...

Страница 10: ...NOTES...

Страница 11: ...10 NOTES...

Страница 12: ...Web Site www dacor com Phone 800 793 0093...

Отзывы: