IMPORTANT 

1.  Before beginning installation, please thoroughly read and become familiar with these instructions. 

2.  Installation and service must be completed by a qualified installer or service agency.

3.   Installer: Please leave these Installation Instructions with the owner.

4.   Owner: Please keep these instructions for local electrical inspector’s use and for future reference.

5.  Read the accompanying Use & Care Manual prior to operating this appliance.

TABLE OF STEPS

Installation Planning 

Pages 2-3

Electrical Connection 

Pages 3-5

Installing the ILB 

Page   6

Installing the REMP 

Page   6

Verifying Proper Operation 

Page   6

Part No. 65265  Rev. D

TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL507, STANDARD FOR ELECTRIC FANS, AND 

CSA C22.2 NO. 113, STANDARD FOR FANS AND VENTILATORS.

NOTES: 

 

Contain helpful hints and tips to facilitate the installation.

CONVENTIONS USED IN THESE INSTRUCTIONS

WARNINGS:

 

Must be followed carefully to avoid personal injury or damage.

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

Remote Blowers

Содержание REMP3

Страница 1: ...rior to operating this appliance TABLE OF STEPS Installation Planning Pages 2 3 Electrical Connection Pages 3 5 Installing the ILB Page 6 Installing the REMP Page 6 Verifying Proper Operation Page 6 P...

Страница 2: ...the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 3: ...ter REMP3 19 483mm 5 13 16 148mm 25 1 2 648mm 8 203mm REMP16 26 660mm 9 9 16 243mm 33 1 2 851mm 10 254mm Model No Electrical Supply Requirements Maximum Duct Length Total Connected Load Blower Rating...

Страница 4: ...The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house supply wire A separate ground wire must be uti...

Страница 5: ...f RV with REMP and CABP3 N1 L1 N2 L2 N2 Gnd BLK WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker GRN WHT L2 BLK BLK WHT Gnd GRN Gnd GRN GRN WHT BLK RV REMP OR CABP3 Wiring of RV with RE...

Страница 6: ...Wiring of DACOR Remote Blower Hood with ILB and REMP L1 N1 Gnd L2 N2 Gnd L2 N2 Gnd GRN WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker BLK GRN WHT BLK GRN WHT BLK REMP HOOD Wiring of D...

Страница 7: ...ions on verifying the proper operation NOTES If the remote blower does not operate properly follow these troubleshooting steps 1 Verify that power is being supplied to the Ventilator and the remote bl...

Страница 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Отзывы: