background image

1

WARNING:

TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE 

FOLLOWING:

a)  Installation work and 

electrical wiring must be 

done by qualified person(s) 

in accordance with all 

applicable codes and 

standards, including fire-rated 

construction.

b)  Sufficient air is needed 

for proper combustion 

and exhausting of gases 

through the flue (chimney) 

of fuel burning equipment 

to prevent back drafting. 

Follow the heating equipment 

manufacturer’s guidelines 

and safety standards such 

as those published by the 

National Fire Protection 

Association (NFPA), and 

the American Society for 

Heating, Refrigeration and 

Air Conditioning Engineers 

(ASHRAE), and the local code 

authorities.

c)  When cutting or drilling into 

wall or ceiling, do not damage 

electrical wiring and other 

hidden utilities.

d)  Ducted fans must always be 

vented outdoors.

e)  Use this unit only in the 

manner intended by the 

manufacturer. If you have 

questions, contact the 

manufacturer.

f)  Before servicing or cleaning 

unit, switch power off at 

service panel and lock 

the service disconnecting 

means to prevent power 

from being switched on 

accidentally. When the service 

disconnecting means cannot 

be locked, securely fasten a 

prominent warning device, 

such as a tag, to the service 

panel.

g)  Blower must not be installed 

in a ceiling thermally insulated 

to a value greater than R40.

h)  Blower must not be installed 

in furnace ductwork.

WARNING:

TO REDUCE THE RISK OF FIRE, 

USE ONLY METAL DUCTWORK.

WARNING:

TO REDUCE THE RISK OF A 

RANGE TOP GREASE FIRE:

a)  Never leave surface units 

unattended at high settings. 

Boilovers cause smoking and 

greasy spillovers that may 

ignite. Heat oils slowly on low 

or medium settings.

b)  Always turn hood ON when 

cooking at high heat or when 

flambeing food (i.e. Crepes 

Suzette, Cherries Jubilee, 

Peppercorn Beef Flambe’).

c)  Clean ventilating fans 

frequently. Grease should not 

be allowed to accumulate on 

fan or filter.

d)  Use proper pan size. Always 

use cookware appropriate 

for the size of the surface 

element.

WARNING:

TO REDUCE THE RISK OF INJURY 

TO PERSONS IN THE EVENT OF 

A RANGE TOP GREASE FIRE, 

OBSERVE THE FOLLOWING:

a)  SMOTHER FLAMES with a 

close-fitting lid, cookie sheet, 

or metal tray, then turn off 

the burner. BE CAREFUL 

TO PREVENT BURNS. If 

the flames do not go out 

immediately, EVACUATE 

AND CALL THE FIRE 

DEPARTMENT.

b)  NEVER PICK UP A FLAMING 

PAN - You may be burned.

c)  DO NOT USE WATER, 

including wet dishcloths 

or towels - a violent steam 

explosion will result.

d)  Use an extinguisher ONLY if:

 1)  You know you have a Class 

ABC extinguisher, and 

you already know how to 

operate it.

 2)  The fire is small and 

contained in the area where 

it started.

 3)  The fire department is being 

called.

 4)  You can fight the fire with 

your back to an exit.

CAUTION:

For General Ventilating Use Only. 

Do Not Use To Exhaust Hazardous 

Or Explosive Materials And 

Vapors.

CAUTION:

To reduce risk of fire and to 

properly exhaust air, be sure to 

duct air outside – Do not vent 

exhaust air into spaces within 

walls or ceilings or into attics, 

crawl spaces or garages.

NOTES: 

1.  Consult a licensed ventilation 

contractor or qualified 

technician for proper 

installation of exhaust 

ducting.

2.  Locate the cooking area for 

minimum cross drafts – away 

from doors and windows, 

when possible.

3.  Ducts must be of adequate 

size and duct runs should 

be as short and straight as 

possible. Where turns are 

necessary, keep turning 

radius as large and smooth as 

possible.

4.  The ducting must be air tight. 

Use a minimum of 2 sheet 

metal screws at every duct 

joint. Then, seal the duct joints 

with a high quality duct tape.

5.  In duct runs less than 10 

equivalent straight feet, the 

remote blower may interfere 

with the cooktop burner 

performance due to the 

high volume of air moved. 

An adjustable damper (not 

included) should be installed 

in the ducting system. The 

damper can be adjusted so 

that proper ventilation and 

cooktop burner performance 

is achieved.

6.  Installation of duct work 

should be carefully planned 

if it is to go under a concrete 

slab floor. The duct trench 

should be boxed to prevent 

collapse from the wet cement. 

Be sure to allow room to 

run the electrical wiring and 

conduit.

IMPORTANT SAFETY INSTRUCTIONS

Содержание REMP3

Страница 1: ...rior to operating this appliance TABLE OF STEPS Installation Planning Pages 2 3 Electrical Connection Pages 3 5 Installing the ILB Page 6 Installing the REMP Page 6 Verifying Proper Operation Page 6 P...

Страница 2: ...the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 3: ...ter REMP3 19 483mm 5 13 16 148mm 25 1 2 648mm 8 203mm REMP16 26 660mm 9 9 16 243mm 33 1 2 851mm 10 254mm Model No Electrical Supply Requirements Maximum Duct Length Total Connected Load Blower Rating...

Страница 4: ...The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house supply wire A separate ground wire must be uti...

Страница 5: ...f RV with REMP and CABP3 N1 L1 N2 L2 N2 Gnd BLK WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker GRN WHT L2 BLK BLK WHT Gnd GRN Gnd GRN GRN WHT BLK RV REMP OR CABP3 Wiring of RV with RE...

Страница 6: ...Wiring of DACOR Remote Blower Hood with ILB and REMP L1 N1 Gnd L2 N2 Gnd L2 N2 Gnd GRN WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker BLK GRN WHT BLK GRN WHT BLK REMP HOOD Wiring of D...

Страница 7: ...ions on verifying the proper operation NOTES If the remote blower does not operate properly follow these troubleshooting steps 1 Verify that power is being supplied to the Ventilator and the remote bl...

Страница 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Отзывы: