Installing the ILB

Mount the ILB using the 4 screws, isolation 

grommets and washers provided in the Parts 

Bag, included in the Instruction Envelope.

Installing the REMP

Mount the REMP to the wall or roof using 

screws, through mounting trim flange.

Verifying Proper Operation

1.  Temporarily re-install the remote blower 

cover, using 2 screws per side (REMP 

ONLY). 

2.  Turn on the power supply at the circuit 

breaker.

3.  Refer to Ventilator Installs for further 

instructions on verifying the proper 

operation.

NOTES:

If the remote blower does not 

operate properly, follow these 

troubleshooting steps:

1.  Verify that power is being 

supplied to the Ventilator and 

the remote blower.

2.  Check the electrical 

connections to ensure that 

the installation has been 

completed correctly.

3.  Repeat the above test.

4.   If the appliance still does not 

work, contact an authorized 

DACOR service company. 

If you are unable to locate 

a DACOR Servicer, please 

contact DACOR at (800) 

793-0093, or visit us on the 

web at www.dacor.com. Do 

not attempt to repair the 

appliance yourself. DACOR 

is not responsible for service 

required to correct a faulty 

installation. 

Содержание REMP3

Страница 1: ...rior to operating this appliance TABLE OF STEPS Installation Planning Pages 2 3 Electrical Connection Pages 3 5 Installing the ILB Page 6 Installing the REMP Page 6 Verifying Proper Operation Page 6 P...

Страница 2: ...the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 3: ...ter REMP3 19 483mm 5 13 16 148mm 25 1 2 648mm 8 203mm REMP16 26 660mm 9 9 16 243mm 33 1 2 851mm 10 254mm Model No Electrical Supply Requirements Maximum Duct Length Total Connected Load Blower Rating...

Страница 4: ...The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house supply wire A separate ground wire must be uti...

Страница 5: ...f RV with REMP and CABP3 N1 L1 N2 L2 N2 Gnd BLK WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker GRN WHT L2 BLK BLK WHT Gnd GRN Gnd GRN GRN WHT BLK RV REMP OR CABP3 Wiring of RV with RE...

Страница 6: ...Wiring of DACOR Remote Blower Hood with ILB and REMP L1 N1 Gnd L2 N2 Gnd L2 N2 Gnd GRN WHT 120VAC 60Hz 15A Supply power from dedicated circuit breaker BLK GRN WHT BLK GRN WHT BLK REMP HOOD Wiring of D...

Страница 7: ...ions on verifying the proper operation NOTES If the remote blower does not operate properly follow these troubleshooting steps 1 Verify that power is being supplied to the Ventilator and the remote bl...

Страница 8: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093...

Отзывы: