7  VENTILATION SYSTEM (PREPARING OVEN FOR INSTALLATION)

This microwave oven/hood is designed for adaptation to three types of hood ventilation systems. Select the type required for 

your installation.
 

 

Vertical Exhaust

 — outside ventilation. Follow installation procedure (A).

   

Horizontal Exhaust

 — outside ventilation. Follow installation procedure (B). 

 Recirculating

 — non-vented, ductless. Follow installation procedure (C). Recirculating requires the use of the included  

charcoal filter.

(A) VERTICAL EXHAuST: OuTSIDE VENTILATION

The unit is shipped assembled for vertical exhaust. Attach the 

exhaust damper assembly to the fan cover on the top of the 

outercase cabinet by sliding it into the slits in the same direc-

tion as the arrow mark. Using a tapping screw 4x12 from the 

installation hardware, tighten into place. See Fig 5. 

(B) HORIZONTAL EXHAuST: OuTSIDE VENTILATION

1. Remove and save 4 screws that hold fan cover in place. Remove fan cover bracket as shown in Fig 6.
2. Remove hood fan unit carefully and slip wires out of wire box. Rotate hood fan unit 90˚ so that exhaust ports are facing rear       

of oven unit. See Fig 7. 

 

 CAUTION: Do not pull or stretch hood fan wiring.

3. Replace hood fan unit into the oven unit. Be careful not to pinch the lead wire between the inner bracket and the hood fan unit. 

See Fig 8.

4. Put the lead wire into wire box.
5. Replace the fan cover bracket. Make sure the fan blades are visible through the rear openings in the oven before proceed-

ing. Attach fan cover bracket to unit with 4 existing screws. See Fig 9. The hood fan unit is now rotated for horizontal exhaust 

operation.

6. Locate the mounting plate and attach the exhaust damper assembly to the back of the mounting plate by sliding it into the slits 

in the same direction as the arrow. See Fig 10. Using a tapping screw 4x12 from the installation hardware, tighten into place.

Figure 6

Figure 7

Fan Cover Bracket

Hood Fan Unit

Exhaust Damper Assembly

Figure 5

Содержание PCOR30

Страница 1: ...the gaps Wall construction should be a minimum of 2 x 4 wood studding and 3 8 or more thick dry wall or plaster lath The mounting surfaces must be capable of supporting a weight of 110 pounds the oven...

Страница 2: ...ection procedures 4 HOOD EXHAUST DUCT When the hood is vented to the outside a hood exhaust duct is required All ductwork must be metal Do not under any cir cumstances use plastic duct work Check that...

Страница 3: ...h 4 3 Top Cabinet Screw 5 x 60 mm 2 4 Flat Washer 30 mm diameter 2 5 Grommet 1 6 Tapping Screw 4 x 12 mm 1 7 Exhaust Damper Assembly 1 8 Deflector 1 9 Mounting Plate 1 The installation hardware items...

Страница 4: ...nd save 4 screws that hold fan cover in place Remove fan cover bracket as shown in Fig 6 2 Remove hood fan unit carefully and slip wires out of wire box Rotate hood fan unit 90 so that exhaust ports a...

Страница 5: ...rly placed Check steps 3 and 4 again 7 Attach the fan cover bracket to the oven unit with 4 existing screws as shown in Fig 9 NOTE The exhaust damper assembly is not required for recirculat ing exhaus...

Страница 6: ...appropriate and put the toggle nuts onto the toggle bolts See Fig 12 Refer to instructions in wall template 3 Position the mounting plate with the toggle bolts attached at the wall location and inser...

Страница 7: ...ward In the case of a non recessed bottom in the top cabinet the hole for the cord may need to be enlarged Remove the carton portions 6 Tighten the two unit mounting screws located in the grease filte...

Страница 8: ...the installation instructions and the wall and top cabinet templates 2 Plug in the power cord 3 Keep the use and care manual MOUNTING DEFLECTOR Secure the deflector with 3 tapping screws 4 x 12mm pac...

Отзывы: