14

Installation Instructions

Cabinet Blower Installation

(Optional: MRV3015M/S, MRV3615M/S)

1. Find the wiring diagram label included with the adapter

kit. Remove the protective backing, and place it over the

existing label on the CABP3 blower as shown.

2. Find the foam tape supplied with the downdraft vent.

Place the blower on the floor as it will be mounted on

the front of the downdraft vent. Remove the backing

from the foam tape, and attach it to the right and left

flanges of the blower base plate.

3. With the exhaust oriented as desired, slide the bottom

flange of the CABP3 blower base plate behind the tab

on the bottom of the adapter mounted to the front of the

downdraft vent.

4. Cover the adapter opening by pushing the blower

against it. Ensure the foam tape creates a good seal on

the right and left side of the opening. Center the blower

base plate horizontally over the adapter’s front opening.

5. Install the adapter top retainer bracket over the blower

base plate flange. Secure it with the 3 wing nuts, lock

washers, and flat washers included with the adapter.

CABP3

Top retainer 

bracket

Insert bottom flange into 

tab at bottom of adapter 

Attach foam

to right/left

flanges

Adapter

New label

Existing 

label

ILHSF or REMP Series Blower Installation

If using a ILHSF or REMP series blower, install it according 

to the blower installation instructions.

Duct Work Installation

 WARNING

For best performance and to keep smoke, odors, and 

combustion byproducts from entering the home, tape all 

duct joints securely.

Install the duct work per the 

Installation Specifications

 

section. Use sheet-metal screws and duct tape to connect 

and seal all pieces. Support the duct weight as needed to 

ensure sealed joints.

Electrical Installation

 

WARNING: ELECTRIC SHOCK HAZARD

• Plug in the downdraft vent 

after

 installation is complete.

• Follow the wiring diagram carefully. Do not change the

factory-wired terminal connections inside the electrical-

access panel for the downdraft vent or blower.

• Route wiring away from hot surfaces.

1. For ILHSF and REMP blower installations, run the wir-

ing/conduit line used to supply power from the downdraft

vent to the blower parallel to the duct work.

2. Remove the cover from the downdraft vent electrical-

access panel.

3. Connect the wiring/conduit to the blower as shown on

pgs. 15 and 17 per local ordinances. Ensure all terminal

connections (including factory-wired connections) are

tight. Replace the electrical-access panel.

Range/Cooktop Installation

Install the range or cooktop as instructed. 

Содержание MRV3615S

Страница 1: ...V48S Includes installation instructions for Dacor cabinet blower CABP3 which is an option for the indicated models Part No 113910 Rev C Use these downdraft vents only with approved Dacor appliances Se...

Страница 2: ...ep these installation instructions for future reference and the local electrical inspector s use Customer Assurance Information All specifications subject to change without notice Dacor assumes no lia...

Страница 3: ...an outlet is available for the appliance Do not remove the third ground prong from the power cord use an adapter plug use an extension cord use a damaged power cord Use a ground fault interrupter GFI...

Страница 4: ...s become blocked Do not let foreign objects be sucked into vent holes Clean the filters and all grease laden surfaces often to pre vent grease fires and maintain performance Clean the appli ance only...

Страница 5: ...for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instructions for cooking appliance Total c...

Страница 6: ...own Tolerances 1 16 1 6 mm unless otherwise stated See Pg 9 for exhaust locations dimensions Max height of downdraft must not exceed cooking unit s max specified counter height See cooking unit s inst...

Страница 7: ...or legs 2 13 16 7 1 cm 1 4 6 mm Top cap with vent down Tolerances 1 16 1 6 mm unless otherwise stated Model Number Top Cap Width A Chassis Width B MRV36 ERS 36 91 4 cm 33 3 8 84 8 cm MRV48 ERS 48 121...

Страница 8: ...f the downdraft vent for connecting blower wiring and strain relief Wire the blower to turn on when the downdraft vent is turned on When installing a remote or in line blower run the blower wiring con...

Страница 9: ...de wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in line blower Cabinet back Front of unit Connection to cabinet blower Blower wiring access h...

Страница 10: ...raft vent s air draw Building codes may require makeup air systems with ven tilation systems that move air greater than the specified movement rate CFM Consult a qualified HVAC specialist when designi...

Страница 11: ...ne of bottom knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust...

Страница 12: ...onnection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Front Exhaust Dimensions CABP3 Bl...

Страница 13: ...e above parts is 15 ft 15 ft 4 ft 2 ft 36 ft The max amount of straight duct that can be used with a REMP16 and the above parts is 60 ft 34 ft 24 ft Equivalent Number of Feet Nominal Duct Elbows and T...

Страница 14: ...cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the prov...

Страница 15: ...wing nuts and 3 flat washers on the front of the unit Discard the 3 lock washers whilch will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape in...

Страница 16: ...m to right left flanges Adapter New label Existing label ILHSF or REMP Series Blower Installation If using a ILHSF or REMP series blower install it according to the blower installation instructions Du...

Страница 17: ...cal Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wir...

Страница 18: ...aft vent Ensure the downdraft vent supplies power to the blower If the vent will not raise properly or makes a scraping sound check for under counter obstructions If the downdraft vent fails to functi...

Страница 19: ...LK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system c...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: