Troubleshooting
9
Problem
May be caused by
What to do
The door will not close properly.
Appliance not level.
Level the appliance. See
Installation
section.
The gasket is dirty.
Clean the door gasket. See
Care and Cleaning
section.
The shelves are not properly
seated.
Re-seat Shelves. See
Care and Cleaning
section.
Alarm sounds and temperature
display
NOT
flashing (door
alarm).
Door has been left open longer
than 60 seconds.
Close door, or touch
POWER
key to disable alarm.
Alarm will reset when door is closed.
Alarm sounds
AND
temperature
display flashes (temperature
alarm).
Door being opened too often.
Keep door closed.
Vent on front of unit is blocked or
dirty.
Remove blockage or clean vent. See
Care and
Cleaning
section.
Long power interruption.
Keep door closed and allow unit to cool to set
temperature.
A large number of bottles have
been added to the unit.
Keep door closed and allow unit to cool to set
temperature.
“
--
” (straight line) appears on
the display.
Temperature display is out of the
range.
Only temperatures within the range of 16 to 99°F (-9 to
37°C) can be displayed. Keep door closed and allow
unit to cool to set temperature.
Vibrations.
Appliance not level.
Level the appliance. See
Installation
section.
The appliance seems to make
too much noise.
A rattling noise may come from the flow of the refrigerant, which is normal. Gurgling sounds
may be caused by the flow of refrigerant in your appliance, which is normal. If temperature
fluctuations occur, the contraction and expansion of the inner walls may cause popping and
cracking noises, which is normal.
Appliance not level.
Level the appliance. See
Installation
section.
E0, E1, E2, E3, E4, E5, E6 or
E7
appears on the display.
Error codes.
Try resetting the controls by disconnecting power to the
unit for 5 minutes, then reconnect. If error code returns,
problem cannot be resolved by user. Call for service.