Preparing for Installation, cont.
Installing the Anti-tip Bracket and Foot, cont.
Floor-Mounting the Anti-tip Bracket, cont.
•
Determine the anti-tip bracket location (see the diagram below). Mark the 4 hole locations on the floor.
•
Determine screw size. Minimum full thread depth (portion of screw threaded into the sub-floor) is 3/8” (1
cm) for wood and 5/8” (1.6 cm) for concrete. (See the SCREW SIZE table, below, for correct screw sizes.)
Attaching the Bracket to a Concrete Floor
1. Drill four 3/8” dia. countersink holes through the flooring but not into the concrete.
2. Through these holes, drill 4 anchor holes
1 ¼” (3.2 cm) into the concrete with a ³/₁₆”
masonry bit. This hole length is longer than
the anchor.
3.
Clean out the holes, and tap in each anchor
so its top is flush with the concrete surface.
4.
Align the bracket and anchor holes, then
insert and tighten the screws.
Attaching the Bracket to a Wood Sub-Floor
1. (Ceramic, stone, other hard flooring over
wood) Drill 4 countersink holes to access
the wood for drilling pilot holes.
2. Drill 4 pilot holes (1/₁₆” dia. bit for #8 screws,
1/8” dia. for #12 screws). Align the bracket
and pilot holes, then insert and tighten the
screws.
Installation Instructions
SCREW SIZE
Sub-floor Type/Floor Cover Thickness
Screw Size
Concrete/wood sub-floor; no floor cover
#8 x 1*
Concrete/wood sub-floor; flooring to ¼” thick
Concrete/wood sub-floor; flooring ¼” – 1/2” thick
#8 x 1 ¼*
Wood sub-floor; flooring 1/2” – 1³/₁₆” thick
#12 x 1 3/4*
Concrete under flooring over 1/2” thick
**
Wood under flooring over 1 ³/₁₆” thick
*Included; **decide required depth using info in Step 3, and purchase.
ANTI-TIP BRACKET PLACEMENT
Dimension
30
36
A
13” (33.0 cm)
13” (33.0 cm)
B
22 1/2” (57.2 cm)
22 1/2” (57.2 cm)
Содержание HIPR30S
Страница 1: ...Installation Instructions Heritage Induction Pro Range HIPR30S HIPR36S Part No 113744 Rev C...
Страница 9: ...9 Product Specifications HIPR30S HIPR36S Ranges HIPR30S HIPR36S...
Страница 24: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...