Installation Requirements
Location Requirements
Electrical Hookups (HIPR 30”, 36”)
Electrical Service Inlets
• Existing utilities may be used if they meet the spec's in this manual.
• The circuit-breaker panel/fuse box must be accessible without moving
the range.
• Junction box/receptacle must not impede placement of the range.
• Locate the junction box so the range can be pulled out for service with-
out being disconnected.
ELECTRICAL-ACCESS DIMENSIONS
Model
A
B*
C**
HIPR30
6 3/4" (17.1 cm)
6 3/4 (17.1 cm)
7/8” (2.2 cm) dia.
HIPR36
12” (30.5 cm)
*Range legs adjusted to lowest height; **hole size may be increased to 1 1/8” (2.9 cm) by removing
conduit bracket in bottom of electrical box.
Electrical Requirements
Follow these directions to reduce risk of property damage, personal injury, or death. The owner shall ensure
that the electrical service meets spec's and the electrical outlet is properly installed by a licensed electrician.
The correct voltage, frequency, and amperage must be supplied to the range from a separate, grounded,
circuit protected by a proper-size circuit breaker or time-delay fuse. (Fuses: fuse both sides of the line (L1, L2).
• The wiring must be long enough that the range can be pulled out for service without being disconnected.
•
If connecting the range via conduit, connect a 4-wire conduit to a 4-wire junction box, or, where local code
permits (excluding new branch-circuit installations), connect a 3-wire conduit to a 3-wire junction box.
Suggested wiring color code: Black, white, red, green.
•
If connecting the range via power cord:
–
A 4-wire appliance cord equipped with a NEMA 14-50P plug connected to a NEMA 14-50R receptacle, or
–
A 3-wire appliance cord (where local code permits) equipped with a NEMA 10-50P plug connected to a
NEMA 10-50R receptacle
–
Appliance cord plug must be UL-listed type SRD or SRDT.
• Wiring to the range must include a strain
relief; must be terminated by tinned leads,
closed-loop terminals, or open-ended spade
lugs with upturned ends; and must connect
to a junction box or receptacle installed by a
licensed electrician.
Model
Required Circuit
Total Connected Load
HIPR30,HIPR36
240 Vac*, 60 Hz, 50 Amp.
11 – 9 kW (49.5 Amp.)
*4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are
for reference only; see the data label (back of range) for exact specifications.