9
Installation Instructions
Anchor Leg
Put nuts/
washers on
studs
Front of
Raised Vent
Floor
Top of vent resting
on countertop
Electrical Access
Panel
Anchor Leg
Example of Installation with Rear Exhaust
(Side View)
REMP Series
Remote Blower
Floor
Wall Board
ER36D or
ER48D Range
ERV configured
for rear exhaust
ERV
Backsplash
Duct work between
ERV and remote
blower
Conduit that supplies power
from ERV to remote blower (see
Electrical Installation
, page 10)
If the unit will exhaust air from the back, attach a
4.
3 1/4” X 10 duct to the vent hole created by removing
the knock-out on the back of the unit.
Loosely attach the anchoring legs to the studs on the
5.
left and right sides of the raised vent using the provided
hex nuts and washers.
Place the vent into the rear of the countertop cutout
6.
with the electrical access panel toward the front.
Adjust the anchoring leg height so that the end caps
7.
are gently resting on the counter, then tighten the hex
nuts.
Secure the anchoring legs to the cabinet floor with the
8.
screws provided.
Installing the Remote Blower and Ducts
Install the remote blower according the remote blower
1.
installation instructions.
Install the duct work between the remote blower inlet
2.
and the exhaust of the raised vent according to the
Installation Specifications
. Use sheet metal screws
and duct tape to connect all of the pieces. Support the
duct weight as necessary to ensure sealed joints.