Dacor Epicure ER36DSCH Скачать руководство пользователя страница 8

2

1, 4

F

G

2

 Cabinet/countertop depth is at discretion of customer but 

cabinet face MUST NOT protrude further than rear of front 

panel, see product dimensions.

3

 Consult local code for exact location requirements.

1

 Vertical to combustible surface from range grate level; if 

installing an overhead vent hood, also check the hood 

specifications for minimum required clearances. 

Non-combustible

surface along 

back wall

recommended

30” (762mm)

Min.

1

36 1/2” 

(927mm)

Max.

13” (330mm)

Max.

4

Suggested

location of 

utilities

3

4

 Not applicable for cabinets more than a horizontal 

distance of 10” (254mm) from the edge of the range.

Planning the Installation

Cabinet Layout

Carefully check the location where the range is to be 

installed. For best performance, the range should be placed 

away from drafts that may be caused by doors, windows and 

heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce 

accumulated smoke in the room, Dacor strongly recommends 

installing a range hood. A range hood should project 

horizontally a minimum of 5 inches beyond the face of the 

cabinets.
All maximum and minimum dimensions and clearances 

shown in the diagrams below must be maintained for safe 

operation.
The range may be installed flush to the rear wall.  

Dacor strongly recommends installing a non-combustible 

material on the rear wall above the range and up to the vent 

hood or installation of a backguard. It is not necessary to 

install non-combustible materials behind the range below the 

countertop height. 
Any openings in the wall behind the appliance or in the floor 

underneath it must be sealed.

CUT-OUT DIMENSIONS

Range Model

F

G

H

ER36D

42” (1067mm)* 

36” (914mm)**

36 1/16” 

(916mm)**

33 ½” 

(848mm)

ER48D

54” (1372mm)* 

48” (1219mm)**

48 1/16” 

(1221mm)**

43 ½” 

(1102mm)

* Recommended   **Minimum

All tolerances: +1/16”, -0 (+1.6mm, -0) 

Unless otherwise stated

Gas and Electrical Service

The shaded area shown denotes the location of the gas 

inlet and the electrical junction box/receptacle. This is the 

recommended location. For replacement purposes, the 

location of the existing utilities may be utilized provided they 

do not interfere with the sides or rear of the range. Check 

local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between 

the gas inlet and the range, for the purpose of turning on or 

shutting off gas to the appliance. 

The installation must allow for the following:

Access to the gas shut-off valve when the unit is installed. 
Access to the remote circuit breaker panel/fuse box, when the 

range is in place.  
The gas supply piping and shut-off valve, and the electrical 

junction box/receptacle must be located so they do not 

interfere with the range when it is installed.
The junction box and gas shut off valve must be located 

so that the range can be pulled out for service while the 

appliance remains connected. 


G

10" (254 mm) Min.
to combustible side
walls above the range
(both sides)

non-combustible

Minumum  Countertop Height:

30 1/4” (768 mm) 

Maximum  Countertop Height:

36 1/2” (927 mm)

rear wall recommended

Backsplash

3/8" (10 mm)

Min. flat countertop

overhang

H

2 13/16"

(71.4 mm)

3

Cutout with Optional ERv Raised vent (Top view)

Standard Cutout with 

Range Hood

APPROVED RAISED VENT MODEL NUMBERS

Range Model

ERV Raised Vent Model

ER36D

ERV36-ER

ER48D

ERV48-ER

IMPORTANT:

 See the raised vent installation instructions 

for the duct and electrical installation requirements. Use 

only the raised vent models specified below.

Содержание Epicure ER36DSCH

Страница 1: ...structions Epicure Range For use with models ER36D ER36D C ER48D ER48D C Part No 100843 Rev S THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD...

Страница 2: ...Burner Components 17 Verifying Proper Operation 18 Installation Checklist 18 Table of Contents IMPORTANT INSTALLER In the interest of safety read these installation instructions completely before you...

Страница 3: ...ven Do not store flammable or explosive materials in adjacent cabinets or areas IMPORTANT Child entrapment and suffocation are not problems of the past Junked or abandoned appliances are still dangero...

Страница 4: ...E SURFACES OF THE OVEN OR COOKTOP DURING OR IMMEDIATELY AFTER USE Do not climb on any part of the appliance Do not leave children alone or unattended in the area around the range Do not allow children...

Страница 5: ...operated without the knobs and trim rings in place For your safety do not use the oven to cook without the convection filter s installed When the filter is not installed the spinning fan blades at th...

Страница 6: ...da It is the owner s responsibility to ensure that the required 4 wire electrical outlet is installed by a licensed electrician as specified below prior to range installation The electrical outlet ins...

Страница 7: ...8 466 7mm 10 3 4 273 0mm 13 11 16 347 7mm 7 8 22 2mm ER48D 3 13 16 96 8mm 18 11 16 474 7mm 9 3 8 238 1mm 13 3 4 349 3mm 1 1 8 28 6mm The diameter on models equipped for use in Canada is 6 4mm larger...

Страница 8: ...IONS Range Model F G H ER36D 42 1067mm 36 914mm 36 1 16 916mm 33 848mm ER48D 54 1372mm 48 1219mm 48 1 16 1221mm 43 1102mm Recommended Minimum All tolerances 1 16 0 1 6mm 0 Unless otherwise stated Gas...

Страница 9: ...rs PN101539 It is taped in place behind the right side of the kick panel when the range is shipped from the factory Leave it in place unless the spill trays need to be removed for service Return it af...

Страница 10: ...uard from its box 24 inch backguard only Use eight 8 hex screws from the backguard kit to attach the support brackets to the range chassis Make sure the gas line is positioned under the bracket as sho...

Страница 11: ...to disengage the hinge catches with the door removed from the oven The hinge springs could release causing personal injury Do not lift or carry the oven door by the door handle NOTE When installing a...

Страница 12: ...ge 3 for power requirements There are four possible ways to wire the range 4 Wire Conduit 3 Wire Conduit where local codes permit 4 Wire Appliance Cord where local codes permit 3 Wire Appliance Cord w...

Страница 13: ...Range Conduit Strain Relief Nut Red Wire White Wire Green Wire Neutral Terminal L1 Terminal L2 Terminal Jumper Removed Black Wire Grounding Screw Connecting 3 Wire Conduit to Range Where Local Code Pe...

Страница 14: ...conduit to the range see page 10 connect the white wire from the appliance to the neutral white supply wire in the junction box Connect the black wire from the appliance to the black L1 power supply...

Страница 15: ...ith External Ground Connection to power supply Separate No 10 minimum copper grounding wire Junction Box Fasten clamp tightly on pipe Wire Nut 4 Places Clamps Metal Water Pipe No 4 copper wire Meter B...

Страница 16: ...the range electrical access cover from the back of the range If using a 4 wire connection loosen the grounding screw and remove the neutral to ground jumper link Remove the conduit bracket from the b...

Страница 17: ...type of gas available check the range data plate see page 3 for location Ranges intended for use with LP gases will have LP as a part of the model number Consult your dealer if the range is not compat...

Страница 18: ...oor Push until the notch on the bottom of each hinge slips over the lower lip of each hinge receptacle Lower the door to the fully opened position Rotate the two hinge locks toward the oven Slowly and...

Страница 19: ...er head Put locating tab in keyed hole STEP 2 Install burner ring Line up ring tabs with head slots Twist back and forth to assure proper seating STEP 3 Install burner cap Ridge on cap must surround t...

Страница 20: ...n completed correctly Repeat the above bake test or burner ignition test If the appliance still does not work contact Dacor Distinctive Service at 877 337 3226 Do not attempt to repair the appliance y...

Страница 21: ...19 Notes...

Страница 22: ...20 Notes...

Страница 23: ......

Страница 24: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...