Dacor Epicure ER36DSCH Скачать руководство пользователя страница 17

Gas Supply Connection

 WARNING

Make sure the gas supply valve is off and that the power 

to the range is turned off at the circuit breaker or fuse box 

prior to connecting the gas line.

Do not apply excessive pressure when tightening gas 

connections and fittings.

Do not use Teflon tape or plumber’s putty on gas flex line 

connections.

For LP installations, the LP gas tank must have its own 

high pressure regulator. This is in addition to the pressure 

regulator provided with the range.

The maximum gas supply pressure to the regulator must 

never exceed 1/2 pound per square inch (psi) or 3.5kPa.

The range and shut-off valve must be disconnected 

from the gas supply piping during any pressure testing 

exceeding 1/2 psi (3.5 kPa).

The range must be isolated from the gas supply piping by 

closing the shut-off valve during any pressure testing at or 

below 1/2 psi (3.5 kPa).

Check all gas lines for leaks as instructed to avoid a fire or 

explosion hazard. Do not use a flame to check for leaks.

NOTE:

 The gas pressure regulator is pre-set at the factory for the 

type of gas intended for use with the appliance. To verify that the 

appliance is compatible with the type of gas available, check the 

range data plate (see page 3 for location). Ranges intended for 

use with LP gases will have “LP” as a part of the model number. 

Consult your dealer if the range is not compatible with the type of 

gas supplied.

Before sliding the range into the cabinet:

Make sure the gas supply valve is in the off position and that 

power to the range is off.
Connect a flexible gas supply line to the gas shut-off valve 

previously installed on the stub out. The gas line needs to be 

long enough to allow the range to be pulled out for service. 
Remove the gas regulator access cover.
Slide the end of the gas line under the back cover into the 

regulator compartment from the bottom. 
Connect the gas line to the regulator.
Turn all cooktop control valves to the “OFF” position. Turn on 

the gas supply.
Check all lines 

and connections 

for leaks using a 

soap and water 

solution. 
After verifying 

that there are no 

gas leaks, turn 

off the gas supply 

valve connected 

to the range 

to the “OFF” 

position.
Replace the 

regulator access 

cover.

1.

2.

3.
4.

5.
6.

7.

8.

9.

Loop and 

Spade Terminal 

Connections

Bare Wire 

Connections

10-50P Plug

L1

L2

Neutral

3 Wire Appliance 

Cord Connection - 

Where Local Code 

Permits

Strain Relief

White Wire

L1 Wire

Neutral Terminal

L1 Terminal

L2 Terminal

L2 Wire

Jumper Link

Back Cover

Regulator 

Connection

Gas Line

Installation Instructions

Содержание Epicure ER36DSCH

Страница 1: ...structions Epicure Range For use with models ER36D ER36D C ER48D ER48D C Part No 100843 Rev S THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD...

Страница 2: ...Burner Components 17 Verifying Proper Operation 18 Installation Checklist 18 Table of Contents IMPORTANT INSTALLER In the interest of safety read these installation instructions completely before you...

Страница 3: ...ven Do not store flammable or explosive materials in adjacent cabinets or areas IMPORTANT Child entrapment and suffocation are not problems of the past Junked or abandoned appliances are still dangero...

Страница 4: ...E SURFACES OF THE OVEN OR COOKTOP DURING OR IMMEDIATELY AFTER USE Do not climb on any part of the appliance Do not leave children alone or unattended in the area around the range Do not allow children...

Страница 5: ...operated without the knobs and trim rings in place For your safety do not use the oven to cook without the convection filter s installed When the filter is not installed the spinning fan blades at th...

Страница 6: ...da It is the owner s responsibility to ensure that the required 4 wire electrical outlet is installed by a licensed electrician as specified below prior to range installation The electrical outlet ins...

Страница 7: ...8 466 7mm 10 3 4 273 0mm 13 11 16 347 7mm 7 8 22 2mm ER48D 3 13 16 96 8mm 18 11 16 474 7mm 9 3 8 238 1mm 13 3 4 349 3mm 1 1 8 28 6mm The diameter on models equipped for use in Canada is 6 4mm larger...

Страница 8: ...IONS Range Model F G H ER36D 42 1067mm 36 914mm 36 1 16 916mm 33 848mm ER48D 54 1372mm 48 1219mm 48 1 16 1221mm 43 1102mm Recommended Minimum All tolerances 1 16 0 1 6mm 0 Unless otherwise stated Gas...

Страница 9: ...rs PN101539 It is taped in place behind the right side of the kick panel when the range is shipped from the factory Leave it in place unless the spill trays need to be removed for service Return it af...

Страница 10: ...uard from its box 24 inch backguard only Use eight 8 hex screws from the backguard kit to attach the support brackets to the range chassis Make sure the gas line is positioned under the bracket as sho...

Страница 11: ...to disengage the hinge catches with the door removed from the oven The hinge springs could release causing personal injury Do not lift or carry the oven door by the door handle NOTE When installing a...

Страница 12: ...ge 3 for power requirements There are four possible ways to wire the range 4 Wire Conduit 3 Wire Conduit where local codes permit 4 Wire Appliance Cord where local codes permit 3 Wire Appliance Cord w...

Страница 13: ...Range Conduit Strain Relief Nut Red Wire White Wire Green Wire Neutral Terminal L1 Terminal L2 Terminal Jumper Removed Black Wire Grounding Screw Connecting 3 Wire Conduit to Range Where Local Code Pe...

Страница 14: ...conduit to the range see page 10 connect the white wire from the appliance to the neutral white supply wire in the junction box Connect the black wire from the appliance to the black L1 power supply...

Страница 15: ...ith External Ground Connection to power supply Separate No 10 minimum copper grounding wire Junction Box Fasten clamp tightly on pipe Wire Nut 4 Places Clamps Metal Water Pipe No 4 copper wire Meter B...

Страница 16: ...the range electrical access cover from the back of the range If using a 4 wire connection loosen the grounding screw and remove the neutral to ground jumper link Remove the conduit bracket from the b...

Страница 17: ...type of gas available check the range data plate see page 3 for location Ranges intended for use with LP gases will have LP as a part of the model number Consult your dealer if the range is not compat...

Страница 18: ...oor Push until the notch on the bottom of each hinge slips over the lower lip of each hinge receptacle Lower the door to the fully opened position Rotate the two hinge locks toward the oven Slowly and...

Страница 19: ...er head Put locating tab in keyed hole STEP 2 Install burner ring Line up ring tabs with head slots Twist back and forth to assure proper seating STEP 3 Install burner cap Ridge on cap must surround t...

Страница 20: ...n completed correctly Repeat the above bake test or burner ignition test If the appliance still does not work contact Dacor Distinctive Service at 877 337 3226 Do not attempt to repair the appliance y...

Страница 21: ...19 Notes...

Страница 22: ...20 Notes...

Страница 23: ......

Страница 24: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: