Dacor EOG303 Скачать руководство пользователя страница 9

Page 7

NOTES:

1.  No adjustment of burner settings is required. All valves and air mixture shutters found in this 

appliance have been factory preset.

2.  Liquid propane (LP) grills should be special ordered from the factory. Liquid propane units are 

identified by the “LP” designation at the end of the model number on the product identification 

chassis tag.

3.  Under extenuating circumstances, outdoor grills may be field converted to operate on LP gas 

or at elevations in excess of 5,000 feet above sea level. However, field conversion must be 

completed by a qualified service agency and authorization must be granted by the factory prior 

to any field conversion.

4.  To prevent damage to the gas regulator, install the regulator only after the grill is mounted in 

its permanent position in the enclosure or cart. Ensure the arrow on the regulator points in the 

direction of the gas flow towards the grill.

STEP 3

Gas and Electrical Supply Requirements 

WARNINGS:

1.  The maximum gas supply pressure to the regulator must not exceed 1/2 pound per square inch.

2.  Verify proper gas supply has been provided. Refer to Table 1.

3.  Do not apply excessive pressure when tightening connections and fittings.

4.  Do not use plumber’s putty or Teflon tape on gas compression connections. It can defeat the 

proper sealing of these fittings. Use plumber’s putty or Teflon tape only on pipe thread fittings.

5.  Turn all outdoor grill control valves to the “OFF” position, then turn on the gas supply. Check 

all supply lines and connections for leaks using a soap and water solution. Do not use a flame 

to check leaks. After verifying that there are no gas leaks, turn off the gas supply to the grill 

by turning the gas shut-off valve to the “OFF” position. Leak testing of the appliance shall be 

conducted according to the manufacturer’s instructions.

6.  For LP cylinder installations, the LP gas cylinder must have its own Certified high-pressure 

regulator (Either Type I or No. 600 Connection).

7.  Natural gas installations will be connected to factory supplied natural gas regulator. Refer to 

Natural gas connections in this manual for details.

8.  Inspect the gas line before and after installation. Also, inspect the line for damage before each 

use of the outdoor grill.

STEP 4

Gas Connections
Natural Gas Connections

Verify gas supply pressures are acceptable based on Table Number 1, on page 6.

The Dacor outdoor cooking products ship with a 3/4 inch nipple, regulator, and 1/2” reducer for gas supply connections.

 

Install a 3/4 inch (19mm) or 1/2 inch (13mm) natural gas supply line, with a shut off valve (not included with the outdoor product), in an 

accessible location under the appliance.  Place the gas supply line and shut off valve inside the base enclosure within a reachable distance 

from the front access doors or open rear area of the enclosure.  Refer to base enclosure planning and cutout dimensions page within this 

manual for additional detail. 

.

Connect the, factory supplied, regulator and gas line nipple at the back right bottom corner of the grill.  Use only approved gas line thread 

compound, regulators, and gas hose.  Be certain the gas flow arrow on the regulator is installed with the flow in the correct direction.  

Install approved flexible gas line from the regulator to the rough gas line shut off valve using the factory supplied regulator.

Check all gas connections for leaking by applying a water and soap solution. If you observe leakage (soap bubbles around any connections) 

do not attempt to operate the grill without correcting the leak.

Содержание EOG303

Страница 1: ...tallation cart Page 5 STEP 3 Gas and electrical supply requirements Page 6 7 STEP 4 Gas connections Page 7 8 STEP 5 Connecting the electrical Page 8 9 STEP 6 Verifying proper operation Page 9 Part No 65249 Rev C TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 58 1998 CGA 1 6 M98 STANDARD FOR OUTDOOR GAS COOKING APPLIANCES IN CANADA INSTALLATIONS MUST BE IN ACCORDANCE WITH THE CURRENT CAN ...

Страница 2: ......

Страница 3: ... appliance under unprotected overhead combustible materials 13 Disconnect the electrical supply before installing or servicing this appliance 14 This appliance must be grounded Connect only to a properly grounded electrical supply Never use an extension cord to operate this appliance 15 Do not operate this appliance with a damaged electrical cord or plug 16 As with any appliance close supervision ...

Страница 4: ... or non combustible base material structures Refer to installation illustrations in the following pages for base cabinet details and for surrounding surface clearances at the countertop and above NOTES 1 A MINIMUM clearance of 8 inches 203mm must be maintained above the countertop material from all vertical materials constructed on the sides or behind the outdoor grill chassis and canopy See detai...

Страница 5: ...he LP gas cylinder shall isolate the cylinder from the burner compartment to provide shielding from radiation a flame barrier and protection from foreign materials such as hot drippings There shall be a minimum clearance of 2 inches 51mm between the floor of the LP gas cylinder enclosure and the ground The design of the outdoor cooking enclosure must allow the LP gas cylinder to be connected disco...

Страница 6: ...410mm 8 3 4 222mm 23 584mm 26 3 8 670mm 27 1 8 689mm 52 1321mm 23 584mm EOG52 Overall Dimensions Overall Width AGAD20 19 1 2 495mm AGAD36 35 7 8 911mm Overall Height 21 533mm Overall Depth 1 4 6mm deep return on frame edge Cutout Width AGAD20 16 3 4 425mm AGAD36 33 1 8 841mm Cutout Height 18 3 4 476mm Cutout Depth 3 76mm Minimum SPECIFICATIONS MEASUREMENTS Accessory Doors 8 3 4 222mm 23 584mm 26 3...

Страница 7: ...nstructions for the appropriate gas and electrical connections and step 6 to verify proper operation 11 Install the right side slide out tank shelf 12 Five gallon LP tanks are the largest recommended tank for installation in the rollout tank drawer Lift up work Surface Fixed wheels Loosen Fasteners 1 2 Gap before install Roll out storage Drawers 2 Roll out LP tank drawer Gas and Electrical Locking...

Страница 8: ...cess for the rotisserie power or an alternate 120VAC duplex outlet location Electrical Supply Requirements The EOG outdoor grills are factory equipped with a three prong grounding plug Correct voltage frequency and amperage must be supplied to the appliance from an isolated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The required voltage frequency and...

Страница 9: ...he grill by turning the gas shut off valve to the OFF position Leak testing of the appliance shall be conducted according to the manufacturer s instructions 6 For LP cylinder installations the LP gas cylinder must have its own Certified high pressure regulator Either Type I or No 600 Connection 7 Natural gas installations will be connected to factory supplied natural gas regulator Refer to Natural...

Страница 10: ...eding with the installation Install the LP regulator and gas hose on the grill main gas stub at the right rear corner of the appliance Follow all regulator and gas line instructions as noted in the warnings above Place the tank into the final position within the base enclosure or cart STEP 5 Connecting the Electrical WARNINGS 1 In the event of a power failure Use Dacor supplied match lite tool 2 V...

Страница 11: ...serie motor and spit at this time Use and Care instruction for proper rotisserie installation be sure to plug only into a grounded receptacle STEP 5 Connecting the Electrical continued Turn ON the main tank valve then turn all burners ON to the high position for approximately 20 seconds to allow the air in the system to purge from the grill and cooktop side burners Once the gas has filled the line...

Страница 12: ...ED LOAD 2 9A ROTISSERIE 1 0A UNIT 1 9A 120VAC 60Hz ELECTRICAL RATINGS GN W BK PLUGS IGNITION PLUG TERMINAL BLOCK N L1 BK W BK BK GN W W FOR OUTDOOR USE SUPPLY CORD STRAIN RELIEF 3 PRONG 7 12 1 2 5 6 W SECONDARY 12VAC DUAL PRIMARY 120VAC INPUT EACH BK BK W R R BR BK BK W W BR BR HALOGEN LIGHT SWITCH BK W BR RIGHT HALOGEN LIGHT 10W 12V LEFT HALOGEN LIGHT 10W 12V BR BR W BR BR GN SUPPLY CORD STRAIN R...

Страница 13: ...Page 11 NOTES ...

Страница 14: ...Page 12 NOTES ...

Страница 15: ......

Страница 16: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093 ...

Отзывы: