Page 6
Model No.
Electrical circuit
required
Total connected
load
Gas type
Manifold pressure
Minimum gas
supply pressure
Liquid Propane
Liquid Propane
120VAC, 60Hz, 15A
120VAC, 60Hz, 15A
120VAC, 60Hz, 15A
120VAC, 60Hz, 15A
2.9 Amps (0.35 Kw)
2.9 Amps (0.35 Kw)
2.9 Amps (0.35 Kw)
2.9 Amps (0.35 Kw)
Natural
Natural
4" Water Column
7" Water Column
11" Water Column
4" Water Column
11" Water Column
12" Water Column
7" Water Column
12" Water Column
EOG303
EOG303LP
EOG36
EOG36LP
EOG52
EOG52LP
EOSB162
EOSB162LP
120VAC, 60Hz, 15A
120VAC, 60Hz, 15A
2.9 Amps (0.35 Kw)
2.9 Amps (0.35 Kw)
Natural
Liquid Propane
4" Water Column
11" Water Column
7" Water Column
12" Water Column
120VAC, 60Hz, 15A
120VAC, 60Hz, 15A
2.9 Amps (0.35 Kw)
2.9 Amps (0.35 Kw)
Natural
Liquid Propane
4" Water Column
11" Water Column
7" Water Column
12" Water Column
STEP 3
Gas and Electrical Supply Requirements
NOTES:
1. If the gas or electric service provided does not meet the product specifications, do not proceed
with the installation.
2. The grounding plug must not, under any circumstances, be cut or removed.
3. Check your local codes for proper method of installation. In absence of local code, this
appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1.
Or CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation
Code.
4. Be certain that the appliance being installed is correct for the gas service being provided.
5. This appliance must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts.
NOTE:
Supply access for the rotisserie power or an alternate 120VAC duplex outlet location.
Electrical Supply Requirements
The EOG outdoor grills are factory-equipped with a three-prong, grounding plug.
Correct voltage, frequency and amperage must be supplied to the appliance from an isolated, grounded circuit which is protected by a
properly sized circuit breaker or time-delay fuse. The required voltage, frequency, and amperage ratings are listed on the product data plate
and are also shown in Table 1.
These outdoor grills must be connected to a power source with copper wire only. The use of aluminum wire may result in unsatisfactory
connections.
It is the owner’s responsibility to ensure that the electrical connection to this appliance is installed by a qualified electrician. The electrical
installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NPFA 70, (or
the latest revision) or Canadian Electrical Code CAN/CGA C22.1, and local codes and ordinances.
Table 1:
Electrical and Gas Supply Requirements
Total connected loads noted above include the ignition system, interior lights, and rotisserie motor. Rotisserie motor should be plugged into the
same grounded outlet power source on the same line as the grill.
Install 120VAC, 15 Amp duplex outlet in an accessible location under the grill inside the base enclosure. Refer to Base Enclosure planning
cutout dimensions for recommended utilities locations.
WARNING:
Electrical grounding instructions
This outdoor cooking gas appliance is equipped with a three-prong grounding plug for your
protection against shock hazard and should be plugged into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from the plug.
Содержание EOG303
Страница 2: ......
Страница 13: ...Page 11 NOTES ...
Страница 14: ...Page 12 NOTES ...
Страница 15: ......
Страница 16: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093 ...