Liquid Propane (LP) Connections

WARNINGS:

1.  A dented or rusty LP tank may be hazardous and should be checked by your LP supplier.

2.  Never use a cylinder with a damaged valve.

3.  A Portable Liquid Propane tank should be a 5 gallon, 20 lb. gas cylinder approximately 12 inches 

(305mm) in diameter and 18 inches (457mm) high, which must be constructed and marked in 

accordance with the specification for Liquid Propane (LP) gas cylinders of the U.S. Department 

of Transportation (DOT) and designed for use with a 5LP-A quick disconnect systems only.

4.  Do not change the regulator/hose assembly with a standard 510 POL tank/valve assembly.

5.  The cylinder must be provided with a shut-off valve terminating in a Liquid Propane (LP) gas 

supply cylinder valve outlet specified, as applicable, for connection No. 5LP-A.

6.  The cylinder supply system must be arranged for vapor withdrawal and provided with a listed 

overfilling prevention device.

7.  If the appliance is stored indoors, the cylinder must be disconnected and removed from the 

appliance.

8.  Cylinders must be stored outdoors in a well vented area out of the reach of children.

STEP 4 

Gas Connections  (continued)

Make sure the LP tank main valve is completely closed before proceeding with the installation.

Install the LP regulator and gas hose on the grill main gas stub at the right rear corner of the appliance. Follow all regulator and gas line 

instructions as noted in the warnings above.

Place the tank into the final position within the base enclosure or cart.

STEP 5

Connecting the Electrical

WARNINGS:

1.  In the event of a power failure. Use Dacor supplied match lite tool.

2.  Verify that the proper electrical power supply has been provided.

3.  Verify that the electrical supply matches the ratings found on the appliance data plate before 

proceeding.

4.  This appliance must be connected to a grounded, metallic, permanent wiring system. 

Alternatively, a grounding conductor should be connected to the grounding terminal or lead on 

the appliance. Failure to do so may result in an electrical shock hazard.

5.  Do not use an extension cord with this appliance. Such use may result in fire, electrical shock, 

or other personal injury.

6.  Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may 

result in an electrical shock hazard.

7.  Do not ground this appliance to a gas supply pipe or hot water pipe.

8.   Keep any electrical supply cord and the fuel supply hose away from any heated surfaces.

NOTE:

  The Dacor outdoor grills are approved for installation on typical whole-house LP gas supply 

systems.  For proper whole-house LP gas installation order Dacor part # 72601.

Содержание EOG303

Страница 1: ...tallation cart Page 5 STEP 3 Gas and electrical supply requirements Page 6 7 STEP 4 Gas connections Page 7 8 STEP 5 Connecting the electrical Page 8 9 STEP 6 Verifying proper operation Page 9 Part No 65249 Rev C TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 58 1998 CGA 1 6 M98 STANDARD FOR OUTDOOR GAS COOKING APPLIANCES IN CANADA INSTALLATIONS MUST BE IN ACCORDANCE WITH THE CURRENT CAN ...

Страница 2: ......

Страница 3: ... appliance under unprotected overhead combustible materials 13 Disconnect the electrical supply before installing or servicing this appliance 14 This appliance must be grounded Connect only to a properly grounded electrical supply Never use an extension cord to operate this appliance 15 Do not operate this appliance with a damaged electrical cord or plug 16 As with any appliance close supervision ...

Страница 4: ... or non combustible base material structures Refer to installation illustrations in the following pages for base cabinet details and for surrounding surface clearances at the countertop and above NOTES 1 A MINIMUM clearance of 8 inches 203mm must be maintained above the countertop material from all vertical materials constructed on the sides or behind the outdoor grill chassis and canopy See detai...

Страница 5: ...he LP gas cylinder shall isolate the cylinder from the burner compartment to provide shielding from radiation a flame barrier and protection from foreign materials such as hot drippings There shall be a minimum clearance of 2 inches 51mm between the floor of the LP gas cylinder enclosure and the ground The design of the outdoor cooking enclosure must allow the LP gas cylinder to be connected disco...

Страница 6: ...410mm 8 3 4 222mm 23 584mm 26 3 8 670mm 27 1 8 689mm 52 1321mm 23 584mm EOG52 Overall Dimensions Overall Width AGAD20 19 1 2 495mm AGAD36 35 7 8 911mm Overall Height 21 533mm Overall Depth 1 4 6mm deep return on frame edge Cutout Width AGAD20 16 3 4 425mm AGAD36 33 1 8 841mm Cutout Height 18 3 4 476mm Cutout Depth 3 76mm Minimum SPECIFICATIONS MEASUREMENTS Accessory Doors 8 3 4 222mm 23 584mm 26 3...

Страница 7: ...nstructions for the appropriate gas and electrical connections and step 6 to verify proper operation 11 Install the right side slide out tank shelf 12 Five gallon LP tanks are the largest recommended tank for installation in the rollout tank drawer Lift up work Surface Fixed wheels Loosen Fasteners 1 2 Gap before install Roll out storage Drawers 2 Roll out LP tank drawer Gas and Electrical Locking...

Страница 8: ...cess for the rotisserie power or an alternate 120VAC duplex outlet location Electrical Supply Requirements The EOG outdoor grills are factory equipped with a three prong grounding plug Correct voltage frequency and amperage must be supplied to the appliance from an isolated grounded circuit which is protected by a properly sized circuit breaker or time delay fuse The required voltage frequency and...

Страница 9: ...he grill by turning the gas shut off valve to the OFF position Leak testing of the appliance shall be conducted according to the manufacturer s instructions 6 For LP cylinder installations the LP gas cylinder must have its own Certified high pressure regulator Either Type I or No 600 Connection 7 Natural gas installations will be connected to factory supplied natural gas regulator Refer to Natural...

Страница 10: ...eding with the installation Install the LP regulator and gas hose on the grill main gas stub at the right rear corner of the appliance Follow all regulator and gas line instructions as noted in the warnings above Place the tank into the final position within the base enclosure or cart STEP 5 Connecting the Electrical WARNINGS 1 In the event of a power failure Use Dacor supplied match lite tool 2 V...

Страница 11: ...serie motor and spit at this time Use and Care instruction for proper rotisserie installation be sure to plug only into a grounded receptacle STEP 5 Connecting the Electrical continued Turn ON the main tank valve then turn all burners ON to the high position for approximately 20 seconds to allow the air in the system to purge from the grill and cooktop side burners Once the gas has filled the line...

Страница 12: ...ED LOAD 2 9A ROTISSERIE 1 0A UNIT 1 9A 120VAC 60Hz ELECTRICAL RATINGS GN W BK PLUGS IGNITION PLUG TERMINAL BLOCK N L1 BK W BK BK GN W W FOR OUTDOOR USE SUPPLY CORD STRAIN RELIEF 3 PRONG 7 12 1 2 5 6 W SECONDARY 12VAC DUAL PRIMARY 120VAC INPUT EACH BK BK W R R BR BK BK W W BR BR HALOGEN LIGHT SWITCH BK W BR RIGHT HALOGEN LIGHT 10W 12V LEFT HALOGEN LIGHT 10W 12V BR BR W BR BR GN SUPPLY CORD STRAIN R...

Страница 13: ...Page 11 NOTES ...

Страница 14: ...Page 12 NOTES ...

Страница 15: ......

Страница 16: ...Web Site www dacor com For a Dealer Service 800 772 7778 Corporate Phone 800 793 0093 ...

Отзывы: