English 21
Ins
tallation ins
truc
tions
Step 4. Install the anti-tip device
WARNING
•
To reduce the risk of tipping, the appliance must be secured by properly
installing the anti-tip device packed with the appliance.
•
All ranges can tip, resulting in personal injury.
•
Tipping ranges can cause burns from spills, personal injury, and/or death.
•
To prevent accidental tipping, install and check the anti-tip bracket following
the instructions and template supplied with the bracket.
Anti-Tip Foot
(location varies)
Anti-Tip Foot
Anti-tip
bracket
An anti-tip bracket and screws, installation
instructions, and template are shipped with
every range (PN 114475). The instructions
include information necessary to complete
the installation of the anti-tip bracket. Read
and follow the instructions on the sheet
and use the template for anti-tip bracket
installation. If not properly installed, the
range could be tipped by you or a child
standing, sitting, or leaning on an open oven
door.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas.
This Dacor gas range can be converted to use LP gas.
(Contact a qualified service technician.)
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orifices to be changed (6 surface burners
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice Size [mm]
LF
16,500
In 0.46 / Out 0.78*2
LR
14,500
In 0.46 / Out 0.74*2
RF
16,500
In 0.46 / Out 0.78*2
RR
14,500
In 0.46 / Out 0.74*2
CF
14,500
1.12
CR
14,500
1.12
Broil
14,500
1.12
Bake
23,000
1.40
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice Size [mm]
LF
22,000
In 0.85 / Out 1.40*2
LR
16,000
In 0.70 / Out 1.17*2
RF
22,000
In 0.85 / Out 1.40*2
RR
16,000
In 0.70 / Out 1.17*2
CF
16,000
1.78
CR
16,000
1.78
Broil
18,000
1.90
Bake
25,000
2.34
Install_DOP36T86GLS_DG68-01106F-00_EN+MES+CFR.indb 21
Install_DOP36T86GLS_DG68-01106F-00_EN+MES+CFR.indb 21
2023-02-28 오전 10:32:46