20 English
Ins
tallation ins
truc
tions
Installation instructions
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Pressure
Regulator
Adapter
Flex Connector
(6-ft max.)
Adapter
Gas Shut-Off Valve
0.5 in or 0.75 in Gas Pipe
Tubing Line to Oven
Burner Control Valve
Tubing Line to Cooktop
Control Manifold
Gas Flo
w int
o R
ange
NOTE
•
If your area requires a rigid pipe hookup, contact a qualified installer, service
agency, or gas supplier.
•
The gas shut-off valve should be installed in an accessible location in the gas
piping, external to the appliance, for the purpose of turning on or shutting off
the gas to the appliance.
•
To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape
with Teflon on all male (external) pipe threads.
1.
Install a manual gas line shut-off valve in the gas line in an easily
accessed location outside of the range.
Make sure everyone operating the range knows where and how to shut
off the gas supply to the range.
2.
Install male 0.5 in (1.3 cm) flare union adapter to the 0.5 in (1.3 cm)
NPT internal thread at the regulator inlet. Use a backup wrench on the
regulator fitting to avoid damage.
When installing the range from the front, remove the 90° elbow for easier
installation.
3.
Install male 0.5 in (1.3 cm) or 0.75 in (1.9 cm) flare union adapter to the
NPT internal thread of the manual shut-off valve, taking care to back up
the shut-off valve to keep it from turning.
4.
Connect flexible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.
5.
When all connections have been made, make sure all range controls are in
the off position and turn on the main gas supply valve. Use a liquid leak
detector at all joints and connections to check for leaks in the system.
WARNING
•
Do not use a flame to check for gas leaks to prevent death, personal injury,
explosion, and/or fire hazard.
•
When using test pressures greater than 1/2 psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve
from the gas supply piping. When using test pressures of 1/2 psig or less to test
the gas supply system, simply isolate the range from the gas supply system
by closing the individual shut-off valve.
WARNING
Do not exceed 25 ft-lbs of torque when making gas line connections.
Overtightening may crack the pressure regulator resulting in gas leak.
Install_DOP36T86GLS_DG68-01106F-00_EN+MES+CFR.indb 20
Install_DOP36T86GLS_DG68-01106F-00_EN+MES+CFR.indb 20
2023-02-28 오전 10:32:46
2023-02-28 오전 10:32:46