background image

All specifications subject to change without notice.

Phone: (800) 793-0093

www.dacor.com

PLANNING

GUIDE

 

All maximum and minimum dimensions and clearances shown in the 

diagrams below must be maintained for safe operation.

 

The range should be placed away from drafts that may be caused by 

doors, windows and heating and air conditioning outlets.

 

Avoid cabinet installations directly above the range. If cabinet 

storage is to be provided above the range, the risk can be reduced 

by installing a range hood that projects horizontally a minimum of 5 

inches beyond the bottom of the cabinets.

 

The range may be installed flush to the rear wall. Dacor strongly 

recommends installing a non-combustible material on the rear 

wall above the range and up to the vent hood or installation of a 

backguard.

 

Any openings in the wall behind the appliance or in the floor 

underneath it must be sealed.

 

The shaded area shown below denotes the location of the gas inlet 

and the electrical junction box/receptacle. This is the recommended 

location. For replacement purposes, the location of the existing 

utilities may be utilized provided they do not interfere with the sides or 

rear of the range. 

 

The junction box and gas shut off valve must be located so that 

the range can be pulled out for service while the appliance remains 

connected.

 

An external manual shut-off valve must be installed between the gas 

inlet and the range for the purpose of turning on or shutting off gas to 

the appliance.

The installation must allow for the following:

 

Access to the gas shut-off valve when the unit is installed.

 

Access to the remote circuit breaker panel/fuse box, when the range 

is in place.

 

The gas supply piping and shut-off valve, and the electrical junction 

box/receptacle must be located so they do not interfere with the range 

when it is installed.

DYRP36DS, DYRP48DS

Discovery 36” and 48” Wide 

Dual Fuel Ranges

Document # PG05-010

Revised 09/03/14   Page 3/3

Cutout tolerances: +1/16” (+1.6 mm), 

-0 unless otherwise stated

CUTOUT WITH OPTIONAL DOWNDRAFT VENT

(TOP VIEW)

APPROVED DOWNDRAFT VENT MODELS

Downdraft Vent Model

For Use With 

Range Model

ERV36-ER

DYRP36D[-C-]S

ERV48-ER

DYRP48D[-C-]S

IMPORTANT: See the downdraft installation instructions

for duct and electrical installation requirements. Use only

the Dacor downdraft vent models specified above.

Cabinet Layout

CUT-OUT DIMENSIONS

Range Model

F

G

H

DYRP36D[-C-]S

42” (106.7 cm)* 

36” (91.4 cm)**

36”

(91.4 cm)**

33 1/2” 

(84.8 cm)

DYRP48D[-C-]S

54” (137.2 cm)* 

48” (121.9 cm)**

48”

(121.9 cm)**

43 1/2” 

(110.2 cm)

* Recommended 

**Minimum

Note 2

F

G

2

 Cabinet/countertop depth is at discretion of customer but 

cabinet face MUST NOT protrude further than rear of front 

panel, see product dimensions.

3

 Consult local code for exact location requirements.

1

 Vertical from range grate level to combustible overhead 

surface; if installing an overhead vent hood, also check  

hood specifications for minimum required clearances. 

4

 Vertical from grate level to combustible surface.

Non-combustible 

surface along back wall 

recommended

10” (25.4 cm) min.

to combustible side

walls above the range

(both sides)

30” (76.2  cm)

min.

1

37 1/2” 

(95.3 cm)

max.

13” (33.0 cm)

max.

5

15” (38.1 cm)

min.

4, 5

5

 This specification does not apply for cabinets more 

than a horizontal distance of 10” (25.4 cm) from the 

edge of the range.

Suggested 

location of 

utilities

 

3

Grate 

level

G

10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)

non-combustible

rear wall recommended

Backsplash

3/8" (1.0 cm)

Min. flat countertop

overhang

H

3” (7.6 cm)

Note 2

Отзывы: