All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
■
All maximum and minimum dimensions and clearances shown in the
diagrams below must be maintained for safe operation.
■
The range should be placed away from drafts that may be caused by
doors, windows and heating and air conditioning outlets.
■
Avoid cabinet installations directly above the range. If cabinet
storage is to be provided above the range, the risk can be reduced
by installing a range hood that projects horizontally a minimum of 5
inches beyond the bottom of the cabinets.
■
The range may be installed flush to the rear wall. Dacor strongly
recommends installing a non-combustible material on the rear
wall above the range and up to the vent hood or installation of a
backguard.
■
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
■
The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended
location. For replacement purposes, the location of the existing
utilities may be utilized provided they do not interfere with the sides or
rear of the range.
■
The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
■
An external manual shut-off valve must be installed between the gas
inlet and the range for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
■
Access to the gas shut-off valve when the unit is installed.
■
Access to the remote circuit breaker panel/fuse box, when the range
is in place.
■
The gas supply piping and shut-off valve, and the electrical junction
box/receptacle must be located so they do not interfere with the range
when it is installed.
DYRP36DS, DYRP48DS
Discovery 36” and 48” Wide
Dual Fuel Ranges
Document # PG05-010
Revised 09/03/14 Page 3/3
Cutout tolerances: +1/16” (+1.6 mm),
-0 unless otherwise stated
CUTOUT WITH OPTIONAL DOWNDRAFT VENT
(TOP VIEW)
APPROVED DOWNDRAFT VENT MODELS
Downdraft Vent Model
For Use With
Range Model
ERV36-ER
DYRP36D[-C-]S
ERV48-ER
DYRP48D[-C-]S
IMPORTANT: See the downdraft installation instructions
for duct and electrical installation requirements. Use only
the Dacor downdraft vent models specified above.
Cabinet Layout
CUT-OUT DIMENSIONS
Range Model
F
G
H
DYRP36D[-C-]S
42” (106.7 cm)*
36” (91.4 cm)**
36”
(91.4 cm)**
33 1/2”
(84.8 cm)
DYRP48D[-C-]S
54” (137.2 cm)*
48” (121.9 cm)**
48”
(121.9 cm)**
43 1/2”
(110.2 cm)
* Recommended
**Minimum
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical from range grate level to combustible overhead
surface; if installing an overhead vent hood, also check
hood specifications for minimum required clearances.
4
Vertical from grate level to combustible surface.
Non-combustible
surface along back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
13” (33.0 cm)
max.
5
15” (38.1 cm)
min.
4, 5
5
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
Suggested
location of
utilities
3
Grate
level
G
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
non-combustible
rear wall recommended
Backsplash
3/8" (1.0 cm)
Min. flat countertop
overhang
H
3” (7.6 cm)
Note 2