 DHW Series Hood Recirculation Kit

Page 2

STEP 1

   Make sure power to the circuit that supplies power to the hood is turned off.

STEP 2

 

Install the duct collar or exhaust cowling on the top of the hood assembly as shown, 

using the screws included with the hood.

STEP 3

   Install the hood on the wall according to the installation instructions included with 

the hood.

STEP 4

   Install the chimney mounting bracket according to the hood installation instructions. 

STEP 5

   Wire the hood according to the hood 

installation instructions. 

STEP 6

   Measure the distance between the top 

of the hood and the ceiling, where the 

chimney mounting bracket is installed. 

STEP 7

   Determine the required duct length by 

subtracting the number from the table 

below from the distance measured in  

step 6.

Hood Model

Subtract

DHW301, DHW361, 

DHW421

4 7/8” 

DHW482

9 5/8” 

STEP 8

   Using tin snips, cut the 8-inch round duct 

to the length determined in step 7.

Instructions

:

Exhaust Cowling Installation - 

Model DHW482

Duct Collar Installation - 

Models DHW301, DHW361 and DHW421

Chimney mounting 

bracket

Measure 

distance