10
Press the <-> button to change the setting.
Press the <Mode> button to skip to the
uncontrolled ascent setup.
U
NCONTROLLED ASCENT SETUP
This function disables or enables the "stop" in
case of uncontrolled ascent. It can be useful
for instructors when practicing emergency
ascents, to prevent the dive computer from
locking out.
On entering this setup, the ascent rate
indicator and the currently selected option
(ON or OFF) will appear. Press <-> to change
the setting. Press <Mode> to skip to SET4.
SET4 - C
ALENDAR CLOCK SETUP
The display initially shows the various parameters
which can be programmed in the SET4 function
group (fig. 7):
"Time" icon.
FIG. 7
To enter SET4, press <Mode> for approximately 2
sec.
To skip to SET5, press and immediately release the
<Mode> button.
To go back to SET3, press and immediately release
the <-> button.
The display shows the current date and time, with the
date digits blinking. The blinking value can be
incremented by pressing <-> (hold down the button
for rapid increment); when the desired value is
reached, press <Mode> to save the new setting and
go on to the next value (month). After setting the
minutes, DARWIN checks the compatibility of the
date and month settings, taking leap years into
account. If the date and month are incompatible with
each other, pressing the <Mode> button returns to
the date setting instead of advancing to SET5,
prompting the user to correct the date. In this way it
is not possible to enter inexistent dates such as April
31 or February 29 2001.
SET5 - C
LEAR RESIDUAL NITROGEN
MEMORY
This set function is used for clearing the residual
nitrogen memory.
The display initially shows the "desat" icon.
To enter SET5, press the <Mode> button for
approximately 2 sec (fig. 8).
FIG. 8
Alternatively, to exit SET mode and advance to
CLOCK mode, press and immediately release the
<Mode> button. To go back to SET4, press and
immediately release the <-> button.
To clear the residual nitrogen memory, press and
hold down the <-> button for at least 6 seconds.
The clearing of the nitrogen memory is confirmed
as shown in fig. 9.
FIG. 9
!
WARNING
This function should only be used by
highly experienced divers who take full
responsibility for the consequences of
disabling the "stop" in case of
uncontrolled ascent.
!
WARNING
The audible alarms should only be
disabled by expert divers who take full
responsibility for the consequences of
this operation.
Darwin.qxd 29/03/2002 16.45 Pagina 10
Содержание DARWIN
Страница 24: ...136 Darwin qxd 29 03 2002 16 47 Pagina 136...
Страница 25: ...137 FIGURES FIG A Darwin qxd 29 03 2002 16 47 Pagina 137...
Страница 26: ...138 Darwin qxd 29 03 2002 16 47 Pagina 138...
Страница 27: ...139 FIGURES FIG B Darwin qxd 29 03 2002 16 48 Pagina 139...
Страница 28: ...140 FIG C Darwin qxd 29 03 2002 16 48 Pagina 140...
Страница 29: ...141 FIGURES FIG D Darwin qxd 29 03 2002 16 48 Pagina 141...
Страница 30: ...142 FIG E Darwin qxd 29 03 2002 16 48 Pagina 142...
Страница 31: ...143 FIGURES FIG F Darwin qxd 29 03 2002 16 48 Pagina 143...