M
AXIMUM
O
2
PARTIAL PRESSURE SETUP
The maximum partial pressure of O
2
, which
triggers an alarm if exceeded, can be
programmed between a minimum of 1.2 bar
(17.4 psi) and a maximum of 1.6 bar (23.2 psi)
in increments of 0.1 bar (1.45 psi) (fig. 4).
Increase the value by pressing the <-> button.
Press the <Mode> button to save the changes
made and advance to SET2.
FIG. 4
SET2 - M
AIN PARAMETER SETUP
The display initially shows the various parameters
which can be programmed in the SET2 function
group (fig. 5):
Altitude program.
"°C" or "°F" temperature units.
"m" or "ft" depth units.
"salt" or "fresh" water.
FIG. 5
To enter SET2 press the < Mode > button for
approximately 2 sec.
To skip to SET3 press and immediately release the
<Mode> button.
To go back to SET1 press and immediately release
the <-> button.
A
LTITUDE PROGRAM
On entering this setup, the currently selected
altitude program (P0, P1, P2, P3) is displayed;
press the <-> button to select the next
altitude program. Press the <Mode> button to
skip to the next parameter.
T
EMPERATURE UNIT SETUP
On entering this setup, the currently selected
unit of measurement will start blinking; use the
<-> button to change the setting. Press the
<Mode> button to skip to the next parameter.
D
EPTH UNIT SETUP
On entering this setup, the currently selected
unit of measurement will start blinking; use the
<-> button to change the setting. Press the
<Mode> button to skip to the next parameter.
F
RESH
/
SEA WATER SETUP
On entering this setup, the currently selected
option (fresh or seawater) will start blinking.
Use the <-> button to change the setting. Press
the <Mode> button to skip to SET3.
SET3 - O
PTIONAL PARAMETER SETUP
The display initially shows the indications of the
parameters which can be programmed in the SET3
function group (fig. 6):
"BEEP".
Ascent rate icons.
To enter SET3, press the <Mode> button for
approximately 2 sec.
To skip to SET4, press and immediately release the
<Mode> button.
To go back to SET2, press and immediately release
the <-> button.
FIG. 6
B
EEPER SETUP
This function is used for inhibiting or enabling
the audible alarms.
On entering this setup, the 'beep' message
appears together with the current setting (ON
or OFF).
DARWIN DIVE COMPUTER
9
ENGLISH
Darwin.qxd 29/03/2002 16.45 Pagina 9
Содержание DARWIN
Страница 24: ...136 Darwin qxd 29 03 2002 16 47 Pagina 136...
Страница 25: ...137 FIGURES FIG A Darwin qxd 29 03 2002 16 47 Pagina 137...
Страница 26: ...138 Darwin qxd 29 03 2002 16 47 Pagina 138...
Страница 27: ...139 FIGURES FIG B Darwin qxd 29 03 2002 16 48 Pagina 139...
Страница 28: ...140 FIG C Darwin qxd 29 03 2002 16 48 Pagina 140...
Страница 29: ...141 FIGURES FIG D Darwin qxd 29 03 2002 16 48 Pagina 141...
Страница 30: ...142 FIG E Darwin qxd 29 03 2002 16 48 Pagina 142...
Страница 31: ...143 FIGURES FIG F Darwin qxd 29 03 2002 16 48 Pagina 143...