In this case, if you increase “Motion Band Range”(F03-03), the “Steady Break point” will be in the
steady range, and indicator will display “Steady” condition. –
(Set value “1” means 50% of Digit)
Zero Tracking Compensation Range setting
F04
5
0
+
9
Due to external causes(Temperature, wind, and dust), there are small
weight difference, indicator will ignore the weight difference and
display Zero.
For this compensation function, indicator will estimate the weight
difference is over the set range during fixed time period.
If there is large weight difference over set range within fixed time
period, the “Zero” is breaking and will find new zero point.
Example) Max. Capacity : 100.00kg, Digit : 0.05kg, F04-03 setting
Zero Tracking Compensation Range : 0.5
ⅹ
digit
ⅹ
F04 set value = 0.0025
ⅹ
3 =
0.075kg
Fixed time period : about 5msec. (Fixed time period will be effected on F06(digital filter) setting)
Auto Zero Range setting
F05
00
00
+
99
Within the “Auto Zero” range, weighing part is steady, indicator will
display current weight as “Zero”
If the weighing part is not “Steady”, indicator will display current
weight.
(Auto Zero Range : ± Set value + weight unit)
※
Using this function, you can get the Zero value without pressing “Zero” key, when there is
remained material in the hopper within Auto Zero Range.
Example) Max. Capacity : 10kg, Digit : 0.02kg, F005-30 setting,
Under this setting, Indicator will display “Zero” automatically, when the weight is within ± 0.30kg(Set value
+ weight unit) and Steady.
about 5msec.
0.075kg
(1.5
ⅹ
digit)
Display Zero
Display Current weight
Zero breaks
Weight
time
Motion Band Range
Motion Band
Range
F03-01
F03-03
Motion Band Range
Zero
22
/
49