Power input

6-24V DC

(12V Recommended)

SIM CARD

MICRO SIM

PUSH-PUSH

Electrical Connection -

VERY IMPORTANT

When  connecting  power  to  the  telephone  it  is  important  that  a  suitably  rated  power  supply  is 

used

 

and the polarity of connection is carefully selected. Suitable power supplies are 12

V

 DC 

battery

 

[can be charged via solar panel] or a constant 12

V

 DC mains Power Pack with a power 

rating of

 

2 Amps or 25 watt. Power consumption will be dependant on usage, please consult 

with your

 

supplier for advice concerning suitable power options for your particular application.

The HOOK LED indicator should be OFF when the telephone is ON HOOK and should be ON

when the telephone is OFF HOOK. During incoming ringing the LED will flash slowly and if a
FAST FLASH is observed this indicates that the telephone is NOT registered on the network.

When configured the INPUT / OUTPUT Terminals monitor a CHANGE OF STATE ONLY and

are volt free contacts.

ANTENNA

CONNECTOR

LOAD Connector

 

(Remote Contact)

 

Activated In call

 

by pressing #1234

 

(# follow

e

d by PIN)

-   +

Содержание RA711-GSM

Страница 1: ...DAC LIMITED USER GUIDE RA711 GSM ...

Страница 2: ...Contents 1 Introduction 2 Mounting Options 3 Electrical Connection 4 Operation 4 SMS Configuration and Status Reporting 5 Commands 11 Quick Start Guide 12 General Care and Maintenance ...

Страница 3: ...M Network 3G or 4G The RA711 GSM telephone is supplied SIM free allowing the user customer to select any mobile network operator as their preferred carrier This user guide is designed to assist with the operation of the RA711 GSM 3G 4G provide simple installation instructions and explain the various programming and reporting parameters available If you require more detailed technical information p...

Страница 4: ...Top of Pole Mounting Top of pole mounting bracket Part No 552642 available from DAC Limited Wall Mounting Inset Flush mounting using In Wall Box Part No RA711 IW or Surface mounting using rear enclosure Part No RA711 OW ...

Страница 5: ... consumption will be dependant on usage please consult with your supplier for advice concerning suitable power options for your particular application The HOOK LED indicator should be OFF when the telephone is ON HOOK and should be ON when the telephone is OFF HOOK During incoming ringing the LED will flash slowly and if a FAST FLASH is observed this indicates that the telephone is NOT registered ...

Страница 6: ...d remotely by using SMS Short Message Service text messages containing correctly formatted commands Incoming command texts allow various parameters to be configured and outgoing log texts can provide log reports regarding the telephone status The messages are sent and received via standard GSM mobile devices mobile telephones and are displayed as standard text messages Typical command parameters w...

Страница 7: ...x 37mV Signal GSM Signal_level Range is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Configure or change USERTEXT recipients CTX In order to configure the USERTEXT recipients person s who receives notification of parame ter change or system error the telephone will require data input via SMS using the CTX command Up to ...

Страница 8: ...ocation of telephone this can be configured via SMS Type New VOICE No s set Battery Battery_voltage current battery voltage e g 11 95V accurate to approx 37mV Signal GSM Signal_level Range is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Configure Location command CLO Each telephone can be programmed with its own unique ...

Страница 9: ...nge is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Status request command REQ In order to clarify telephone status a request can be made to establish system parameters and health status Upon receipt the telephone replies with a USERTEXT message to the command originator REQ1234 The originator the person who sent the SM...

Страница 10: ...nfigure Command Configure Parameters Command CFG This describes the parameters that can be configured monitored and should only be used following consultation with your supplier or with DAC Limited direct IO 1 2 output 0 relay off 1 relay on Auto answer after this number of network RING indicators 0 25 00 off Auto on hook time minutes 0 20 00 off Handset volume 0 5 5 highest Handsfree volume 0 5 5...

Страница 11: ...l the telephone telephone number determined by SIM card however the telephone will not dial out until a number is stored in the internal memory 6 If required store a number in the internal memory by utilising the CVC Configure Voice Call command Send a text message to the telephone as follows CVC1234 44XXXXXXXXX You will receive a message back from the telephone confirming that you have configured...

Страница 12: ...maintenance To clean wipe with a damp cloth Do not use any abrasive cleaners on the telephone as this may cause the telephone to become discoloured DISTRIBUTED BY DAC Limited Union Mill Watt Street Sabden Lancashire BB7 9ED Tel 01282 447000 Fax 0845 280 1915 www daclimited co uk ...

Отзывы: