DOL , stator and 
autotransformer starting 
Motor cables are marked with 
letters  U1,  V1,  W1  and  have 
to  be  connected  to  control 
panel  terminals,  respectively: 
U1,  V1,  W1  for  clockwise 
rotation 

(seen 

from 

motor/pump  coupling).  For 
counterclockwise 

rotation, 

reverse two of the cables. 
 
 
 
 

6.5  Further  instructions  for  six-cables 
motors terminals connection

 

 
Six  cables  motors  can  be 
started  with  a  Star/Delta 
starter  only  if  main  voltage  is 
at  least  equivalent  to  the 
motor minimum rated voltage. 

 

 
 

 
 
 

To  obtain  the  correct  rotation 
direction,  find  main  terminals 
L1,  L2  and  L3  as  previously 
described. 

 

 

7.  COMMISSIONING AND STARTUP 
7.1 Startup 

 

Start  the  pump  with  gate  valve  half  opened  to 
check  rotation  direction.    When  the  water  starts 
flowing,  close  further  the  gate  valve:  pressure 
rating should be higher than rated pressure value. 
If  this  is  not  the  case,  the  rotation  direction  is 
wrong.  Reverse  two  motor  phases  to  restore  the 
correct rotation direction.                        

 

The  pump  should  not  run  in  the  wrong  sense  for 
more than 3 minutes.

 

Close then the gate valve to 

about  the  half  of  its  full  opening  and  leave  the 
pump  running  for  a  minute.  Stop  then  the  pump 
for  five  minutes  to  allow  the  dissolution  of  air 
bubbles  which,  if  present,  might  endanger  shaft 
lubrication. 

 

Start  the  pump  and  gradually  open  the  delivery 
gate valve till the water shows free of sand, or till 
the suspended sand has dropped to a sufficiently 
low percentage (40 g/m³). 

 

Before  definitively  commissioning  the  pump, 
remove starter fuses and check the electric circuit 
integrity  with  an  ohm-meter  to  make  sure  there 
have  been  no  damages  when  lowering  the  pump 
in the well. 
If the results are negative, lift the group again and 
check it thoroughly. 

 

For three-phases units, the electric resistance value 
should be nearly the same for each phase. 

 

Check  insulation  resistance  to  the  ground  (i.e. 
between  cable  end  and  discharge  pipe)  using  a 
megahoms-meter. Minimum value to the ground for 
a new pump is 10 megahoms with cold motor. 

 

However, if some misfunctioning is detected during 
startup, stop immediately the pump and investigate 
the problem. 

 

Check  also  that  the  pump  runs  within  its  operating 
limits  and  that  voltage  rates  reported  on  control 
panel do not exceed motor nameplate rated values. 

 

If necessary, partially close gate valve or adjust the 
intervention of pressure switches. 

The  system  should  be  fully  completed 
before  starting  the  pump,  especially  for 
what  concerns  electrical,  mechanical  and 
hydraulical components. 
All  safety  systems  must  be  correctly 
operating. 
The  pump  cannot  run  for  more  than  3 
minutes  with  the  gate  valve  closed  to 
avoid overheating of the unit. 

 

7.2 Operation 

The  max.  number  of  possible  startups  /  hour  depends 
from motor power and starter type. 

 

Up to 100 Hp = 10 startups / hour 
100/200 Hp = 8 startups / hour 
above 200 Hp = 5 startups / hour 

 

If  the  pump  does  not  start,  avoid  insisting  without 
having before investigated the reason. 
All  motors  can  afford    ÷  5%  voltage  deviation  from 
rated voltage values. 

 

7.3 Running tests 

In  case  of  pump  misfunctioning,  perform  the  following 
tests to find out the probable reasons: 

 

FIRST TEST

 

 

Close fully the gate valve. 

 

Note at startup the AMPS absorbed. 

 

Note during operation. 

 

Note  pressure  as  reported  by  the  pressure  gauge 
on delivery. 

 

Note  vertical  distance  between  water  level  and  the 
gauge dial center. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Connection  

Electrical                                               

equipment 

 

Connection  

Electrical                  

equipment 

 

 

Содержание SS6

Страница 1: ...NDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERHÅLLSANVISNING Ο ΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ KULLANIM VE BAKIM TALİMATLARI ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ INSTRUCŢUNI PENTRU INSTALARE ŞI ÎNTREŢINERE INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO INSTRUKCJE OBSŁUGI I KONSERWACJI INSTALLÁCIÓS ÉS KARBANTARTÁSI UTASÍTÁS ا دات إر وا SS6...

Страница 2: ...AIS page 9 ENGLISH page 17 DEUTSCH seite 24 NEDERLANDS bladz 32 ESPAÑOL pág 40 SVENSKA sid 48 ΕΛΛΗΝΙΚΑ σελ 56 TÜRKÇE sayfa 64 РУССКИЙ cтр 72 LIMBA ROMÂNĂ pag 80 PORTUGUÊS pág 88 POLSKI str 96 MAGYAR oldal 104 112 ªRte IZk ...

Страница 3: ...hat they do not play with the appliance Ensure that the product has not suffered any damage during transport or storage Check that the outer casing is unbroken and in excellent conditions 1 1Safety Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country where the product is installed for Italy CEI 64 2 1 2 Respons...

Страница 4: ...antifreeze mixture to prevent internal freezing up to 30 C Motors should not be stored or installed with lower temperatures or for periods longer than 12 months however if this is unavoidable turn the shaft by hand once a month If the motor has been stored for more than 12 months disassemble it and check rotating parts and thrust bearing Just before installation drain completely the motor from the...

Страница 5: ...brackets placed alternately on the pump column pipe Proceed in the following way a Connect the first column section to the pump delivery nozzle after having placed a splitted supporting bracket at the opposite end of the pipe In case of threaded column pipes place by the upper end the suited threaded sleeve to avoid possible sliding between pipe and bracket b Move the assembly with a hoist and low...

Страница 6: ...no cuts cracks scratches or other damages If two cables have to be joined in parallel pay extreme attention when connecting cables of the same color 6 2 Electric system The motor is connected by the supply cable to the control panel which contains the necessary control and protection devices Since every difficulty either mechanical or electric will damage almost automatically the motor windings it...

Страница 7: ...ages when lowering the pump in the well If the results are negative lift the group again and check it thoroughly For three phases units the electric resistance value should be nearly the same for each phase Check insulation resistance to the ground i e between cable end and discharge pipe using a megahoms meter Minimum value to the ground for a new pump is 10 megahoms with cold motor However if so...

Страница 8: ...onstruction features the pump and motor group easily disassembled and re assembled with normal metric size shop tools If the pump adopts a non return valve consider the additional weight of the water filled column besides the group weight and use therefore a suited hoist We suggest to employ specialized personnel for assembling and disassembling 9 2 Assembling the pump motor group Check the free r...

Страница 9: ...he pump is running A Too low voltage B Overload due to sand clogging bearings tend to saize C Single phase a voltage 1 5 2 times higher than normal runs through motor windings so the starter trips stopping the unit D The starter is installed in a too warm place E The starter in not correctly calibrated F Electropump blocked in a crooked sinkhole with consequent abnormal value of the absorbed curre...

Отзывы: