ENGLISH
26
7.24
AE: Enabling the anti-block function
The anti-blocking function avoids mechanical blocks in the case of long inactivity; it acts by periodically rotating the pump.
When the function is enabled, every 23 hours the pump performs an unblocking cycle lasting 1 min.
7.25
AF: Enabling the anti-freeze function
If the antifreeze function is enabled the pump is automatically rotated when the temperature reaches values close to freezing point, in order to
avoid breakages of the pump.
7.26
Manual disabling of the pump
Forcibly prevents the pump from starting.
7.27
Enabling float function
Enables or disables the float stop function.
7.28
Enabling stop with level sensor
Enables or disables the pump stop function according to the minimum tank level set.
7.29
Minimum tank level
Sets the tank level below which the pump stops. For the setting to take effect, the stop function with level sensor must be enabled.
7.30
Tank filling level
Value % which expresses the amount of water available in the tank in relation to the maximum level detected during the pump history. To reset
the maximum tank level detected in the pump history, simply remove the level sensor from its seat and power the pump for at least 5 sec.
7.31
Setting Tank Side 1
Sets side 1 of the tank base size or the diameter of a circular tank (the interpretation changes depending on the value assigned to Side 2).
If Side 1 is set to 0, all functions related to the tank level are disabled.
7.32
Setting Tank Side 2
Sets side 2 of the tank base size. By setting SIDE 2 = 0, the tank is assumed to be circular in shape with a diameter equal to SIDE 1.
7.33
Power Shower
Allows the delivery pressure to be increased for a limited time. It is used to allow the user to benefit easily from a pressure boost of the system
without having to change the SP parameters and then restore them to the old values. It is activated when needed by the user. It deactivates
automatically after the set time has elapsed. If during the time that the function is active, a new Start is sent or the duration time is changed, the
timer is reset and the time count restarts from the beginning.
7.33.1
Power Shower Command
Comando di Start/Stop della funzionalità Power Shower.
7.33.2
Power Shower Duration
Sets the duration of the function (min 5’; max 120’).
7.33.3
Power Shower remaining time
Countdown of Power Shower operating time. When it reaches 0 the function is no longer active and the pump returns to pressurise
the system at setpoint pressure.
7.34
Sleep mode
Allows the delivery pressure to be reduced for a period of time. It is used to reduce possible restarts, have a better acoustic comfort and
decrease consumption during the night. Once set, it is automatically activated and deactivated every day at the desired time band.
7.34.1
Sleep Mode Enabling
Command for enabling Sleep Mode function.
7.34.2
Sleep Mode start time
Sets the time of day at which Sleep Mode will be activated.
7.34.3
Sleep Mode Duration
Sets the duration of the function (min 5’; max 24h).
7.34.4
Sleep Mode remaining time
Countdown of Sleep Mode operating time. When it reaches 0 the function is no longer active and the pump returns to pressurise the system at
setpoint pressure.
Содержание ESYBOX DIVER
Страница 4: ...Fig 6 Fig 7 Fig 8 Fig 9 ...
Страница 5: ...Fig 10 Fig 11 Fig 12 Fig 13 ...