In Basic mode, once the condition of recurrence is detected the pump stops and remains waiting to be manually reset.  

This condition is communicated to the user with the "ANTICYCLING” message. After the leak has been removed, you can manually force restart 

by sending the Error Reset command.  

In Smart mode, once the leak condition is detected, the parameter RP is automatically increased to decrease the number of starts over time. 

 

8.1.3

 

Anti-Freeze (Protection against freezing of water in the system) 

The change of state of water from liquid to solid involves an increase in volume. It is therefore essential to ensure that the system does not 

remain full of water with temperatures close to freezing point, to avoid breakages of the system. This is the reason why it is recommended to 

empty any electropump that is going to remain unused during the winter. However, this system has a protection that prevents ice formation 

inside by activating the electropump when the temperature falls to values close to freezing point. In this way the water inside is heated and 

freezing prevented. 

 

 

The Anti-Freeze protection works only if the system is regularly fed: with the plug disconnected or in the absence of 

current the protection cannot work. 

However, it is advised not to leave the system full during long peri-  ods of inactivity: drain the system  accurately 

through the drainage cap and put it away in a sheltered place.  

 

8.1.4

 

“PB” Blockage due to supply voltage outside specifications 

This occurs when the allowed line voltage at the supply terminal assumes values outside the specifications. It is reset only automatically when 

the voltage at the terminal returns within the allowed values. 

 

8.2

 

Manual reset of error conditions 

In error status, the user can cancel the error and force a new attempt by sending the Error Reset command.  

8.3

 

Self-reset of error conditions 

For some malfunctions and blockage conditions, the system attempts automatic self-reset. 

The auto self-reset procedure concerns in particular:  

“BL” 

Blockage due to dry operation

 

“PB” 

Blockage due to line voltage outside specifications 

“OT” 

Blockage due to overheating of the power stages  

“OC” 

Blockage due to motor overload 

“BP” 

Blockage due to fault of the pressure sensor 

For example, if the system is blocked due to dry running, the device automatically starts a test procedure to check whether the machine is 

really left definitively and permanently dry

. If during the sequence of operations an attempted reset is successful (for example, the water 

comes back), the procedure is interrupted and normal operation is resumed. Table shows the sequences of the operations performed by the 

device for the different types of blockage. 

Automatic resets of error conditions

 

Indication

 

Description

 

Automatic reset sequence

 

BL

 

Blockage due to dry operation 

One attempt every 10 minutes for a total of 6 attempts.

 

One attempt every hour for a total of 24 attempts.

 

One attempt every 24 hours for a total of 30 attempts.

 

PB

 

Blockage due to line voltage outside 

specifications

 

It is reset when it returns to a specific voltage.

 

OT

 

Blockage due to overheating of the power stages

 

It is reset when the temperature of the power stages returns 

    within the specifications.

 

OC

 

Blockage due to motor overload

 

One attempt every 10 minutes for a total of 6 attempts.

 

One attempt every hour for a total of 24 attempts.

 

One attempt every 24 hours for a total of 30 attempts.

 

Table 5 Self-reset of blockages 

 

9

 

FACTORY SETTINGS 

The device leaves the factory with a series of preset parameters which may be changed according to the user’s requirements. Each change of 

the settings is automatically saved in the memory and, if desired, it is always possible to restore the factory conditions. 

 

9.1

 

Restoring the factory settings 

It restores the value of all configuration parameters to factory default values.  

 

NOTE: Once the factory values have been restored it will be necessary to reset all the parameters that characterise the system (gains, setpoint 

pressure, etc.) as at the first installation. 

Содержание ESYBOX DIVER

Страница 1: ...Я ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ RU POKYNY K INSTALACI A ÚDRŽBĚ CZ ASENNUS JA HUOLTO OHJEET FI INSTALLATIONS OCH UNDERHÅLLSANVISNING SE INSTRUCŢIUNI PENTRU INSTALARE ŞI ÎNTREŢINERE RO ΟΔΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ GR KURMA VE BAKIM BİLGİLERİ TR INSTRUKCJA MONTAŻU I KONSERWACJI PL INSTALLÁCIÓS ÉS KARBANTARTÁSI KÉZIKÖNYV HU INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO PT ИНСТРУ...

Страница 2: ...strana 106 sivu 121 sid 136 pag 151 σελίδα 166 sf 181 strona 196 oldal 211 pag 226 Стр 242 ITALIANO ENGLISH FRANÇAIS DEUTSCH NEDERLANDS ESPAÑOL РУССКИЙ ČEŠTINA SUOMI SVENSKA ROMÂNĂ ΕΛΛΗΝΙΚΑ TÜRKÇE POLSKI MAGYAR PORTUGUÊS БЪЛГАРСКИ 258 اﻟﺻﻔﺣﺔ اﻟﻌﺮﺑﯿﺔ اﻟﻠﻐﺔ ...

Страница 3: ... اﻟﺸﻜﻞ Fig Fig Image Abb Afb Fig Рис Obr Kuva Fig Fig Εικ Şekil Rys Ábra Fig Фиг Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 ...

Страница 4: ...Fig 6 Fig 7 Fig 8 Fig 9 ...

Страница 5: ...Fig 10 Fig 11 Fig 12 Fig 13 ...

Страница 6: ...stallation Installation and operation must comply with the local safety regulations in force in the country in which the product is installed Everything must be done in a workmanlike manner Failure to respect the safety regulations not only causes risk to personal safety and damage to the equipment but invalidates every right to assistance under guarantee The products in question in this discussio...

Страница 7: ...le noise radiated towards other appliances it is recommended to use a separate electrical duct to supply the inverter The appliance may be used by children over 8 years old and by persons with reduced physical sensory or mental capacities or who lack experience or knowledge on condition that they are under supervision or after they have received instructions concerning the safe use of the applianc...

Страница 8: ...ng them away See chapter Maintenance and Cleaning 1 2 Pumpable Liquids Only use the pump in clean water The pump must not be used to pump salt water sewage inflammable corrosive or explosive liquids e g petroleum petrol thinners greases oils The temperature of the liquid to be pumped must not exceed 50 C 122 F If the pump is used for the domestic water supply respect the local regulations of the a...

Страница 9: ... in a location that is not exposed to freezing When the pump remains inactive at a temperature lower than 0 C it is necessary to ensure that there is no water residue which could freeze and damage it Hang the pump by passing the rope through the hole provided see figure 5 Do not hang the pump by the handle Do not install check valves near the pump delivery distance less than 1 metre 3 28ft The pum...

Страница 10: ...which prevents water hammer In case of ice in the delivery pipe with a submerged pump this valve protects the pump from breakage Installation in a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use rigid metal pipes to hang the pump and secure the pipes with brackets at the top of the well Installation...

Страница 11: ...al connection 4 FIRST INSTALLATION The pump and the DCONNECT BOX 2 if present must be connected to the same power mains avoiding their being galvanically separated as for example due to the presence of open isolation transformers or switches even single phase ones In particular condominium or industrial contexts where single phase users can be connected to different phases of the three phase distr...

Страница 12: ...mp connects to the DCONNECT BOX 2 via the Power Line Communication protocol referred to as PLC Thanks to this communication channel the user can monitor the pump status and actively interact through the app In order to communicate ESYBOX DIVER and DCONNECT BOX 2 must be associated with each other and this operation is already done in the factory Once powered the two units connect in a few minutes ...

Страница 13: ...nd select the product Dconnect Box2 b Press the Dconnect BOX2 key for 5s until the wifi led blinks c Follow the instructions on the APP until the wifi led stays on with a steady light and the APP shows the screen of the DCONNECT BOX2 3 Only if Dconnect BOX2 has a previous association delete any previous association on DCONNECT BOX 2 Advanced Menu Remove PLC association ...

Страница 14: ...tion with the APP and the DConnect Cloud service consult also the online documentation and watch the demonstration videos All the necessary information is available on the site www internetofpumps com or www dabpumps com 6 OPERATION Once the electropump is primed the system starts regular operation according to the configured parameters it starts automatically when the tap is turned on supplies wa...

Страница 15: ...wered in rigid systems for example with iron pipes To keep the pressure in the system constant the inverter performs a type PI control on the measured pressure error Depending on this error the inverter calculates the power to be supplied to the motor The behaviour of this control depends on the set GP and GI parameters To cope with the different behaviour of the various types of hydraulic plants ...

Страница 16: ...f the tank base size By setting SIDE 2 0 the tank is assumed to be circular in shape with a diameter equal to SIDE 1 7 33 Power Shower Allows the delivery pressure to be increased for a limited time It is used to allow the user to benefit easily from a pressure boost of the system without having to change the SP parameters and then restore them to the old values It is activated when needed by the ...

Страница 17: ...P1 Blockage due to reading error on the delivery pressure sensor PB Blockage due to supply voltage outside specifications OT Blockage due to overheating of the power stages OC Blockage due to motor overload NC Blockage due to motor disconnected Ei Blockage due to i th internal error Vi Blockage due to i th internal voltage out of tolerance EY Block for cyclicality abnormal detected on the system T...

Страница 18: ...ditions the system attempts automatic self reset The auto self reset procedure concerns in particular BL Blockage due to dry operation PB Blockage due to line voltage outside specifications OT Blockage due to overheating of the power stages OC Blockage due to motor overload BP Blockage due to fault of the pressure sensor For example if the system is blocked due to dry running the device automatica...

Страница 19: ...n or does not stay on Pump is not powered Check power supply No water Restore the water level Utility at a level higher than the system restarting pressure level Increase the system restarting pressure level by increasing SP or decreasing RP La pompa non si arresta Leak in the system Check the system find and eliminate the leak Impeller or hydraulic part clogged Dismantle the system and remove the...

Страница 20: ...essary to wait 25 minutes with the machine powered for the automatic restoration of the locked status Table 7 Troubleshooting 11 FIRMWARE UPDATE The ESYBOX DIVER firmware can be updated via cloud or app using DConnect Box 2 When a new firmware is available the interface sends a notification and gives the user the opportunity to start the update 12 CLEANING STORAGE MAINTENANCE The pump does not req...

Отзывы: